catalogue search
|
You may also be interested in
DC motor, Carbon brush, AC motor, Inverter duty motor, Electric motor
Text version of the page
5
Standards IEC600 34-1
Insulation
Class H
Temperature rise
Class F
Stator
Fully square frame laminated, low loss, insulated on both
faces. The laminations are welded together and the
number of air channels through the iron core ensure a
good heat transfer.
Winding
Conceived in order to withstand voltage peaks (du/dt)
generated by the inverter.
Thermal protection
PTC 140°C thermistors (3 in series) in stator winding. PTC
signal cable terminals are located into the terminal box.
Rotor
Consists of a core of laminations with the same magnetic
properties as the stator laminations, and a squirrel cage
made of die-cast aluminium or copper bars for larger
frames. The skewed rotor core has an optimized number
of slots and cooling channels for smooth running, high
performance and good heat transfer.
Vibration Class and balancing
AMP motors are manufactured as standard to meet
vibration class A and balanced with half key.
Class B is available on request.
Vibrations are expressed in mm/s, rms, using free suspension
method and measured under no load.
Center height - mm
Vibration
Grade
112 H 132 132 280
Displ
ėm
Vel
mm/s
Acc
m/s˛
Displ
ėm
Vel
mm/s
Acc
m/s˛
Displ
ėm
Vel
mm/s
Acc
m/s˛
A 25 1.6 2.5 35 2.2 3.5 45 2.8 4.4
B 11 0.7 1.1 18 1.1 1.7 29 1.8 2.8
Basic design
Motor Size 112 132 160 180 225 280 355
Stator
Material Magnetic lamination
Stator winding Copper wire with special insulation for inverter supply
End shields Material Cast Iron
Bearing
D-End/ND-End 6308 6310 6214 6216 6220 6224 6230
2RS C3 C3 C3 C3
Insulated bearing recommended > 100 kW
Axially locked bearings N-End
Lubrication Greased for life Regreasable
Terminal box Steel Cast Iron
Flange Steel
Cooling system Aluminium motor + Steel fan housing
Rotor
Material Magnetic lamination
and pressure die-cast aluminium and copper bars
Balancing method Half key balancing
Cooling and terminal box position
Standard in IP23:
Cooling by radial mounted 3-phase fan blower located on
top at N-End of the motor. Terminal box on the Right
Hand Side (facing D-end). Cable outlet towards D-End.
The fan blower is supplied without air filter as standard.
Filter on request.
Standard in IP54:
Cooling by axial compact mounted 3-phase fan blower,
induced draught, located at the back of the motor.
Terminal box on top of the motor. Cable outlet towards
D-End.
Standard in IP55:
Cooling by axial mounted 3-phase fan blower located at
the back of the motor. Terminal box on top of the motor.
Cable outlet towards D-End. Cooling by radial mounted
fan blower is possible.
Other cooling forms (in IC666, IC86W with exchanger)
and positions for fan, terminal box and cable outlet are
available on request.
Mounting forms
Standard IP23 Standard IP54/55
112-355: IM1001/B3 112-160: IM 2001 / B35
180-355: IM1001/ B3
For more information, see the IEC flange board page 8.
Bearings
Grease lubricated ball bearings are provided as standard
for direct drive application. For pulley-belt drive, please
contact our sales office.
T-T recommend to use N-End insulated bearing or similar
solution for output power above 100kW.
Painting
The standard AMP surface finish has excellent resistance
properties. The painting system is suitable for humid
environments. Standard colour of the motor is blue
according to Munsell 8B 4.5/3.25 (similar to RAL5024).
Paint thickness 60 microns.
|