catalogue search
|
You may also be interested in
Inverter duty motor, Carbon brush, Asynchronous motor, DC motor, Electric motor
Text version of the page
19
Motor Characteristics
Blower characteristics
Electrical Data (at 400V)
AMP 132-4C / IP23S
Ø42
45
12
8
M16
12
132
230
216
264
Ø12
410
78 175
419
542
260
185 225
315
110 89 475 155
Ø120
190
529.5
295.5 347
871.5
80
621
Encoder with cover
Filter
on request
A
A (1:4)
Frequency (Hz) 50/60 Number of phases 3
Voltage (V) 400/460 Mounting Radial
Speed (min-1) 2820/3385 Type of cooling fan Force draught
Power (kW) 0.55/0.63 Internal Static Air Pressure Drop (Pa) 500
Current (A) 1.33/1.16 Required cooling Air flow (m3/h) 400
nN
min-1
PN
kW
TN
Nm
IN
A
n1
min-1 cos ö ç fN
Hz
500 16 304 36 800 0.79 0.81 18.9
1000 31 298 65 1600 0.80 0.86 35.8
1500 45 287 90 2400 0.80 0.90 52.10
2000 55 264 108 3200 0.80 0.92 68.9
3000 63 201 118 4800* 0.81 0.95 101.9
Degree of Protection IP23 S Cooling IC06
Rotor Inertia J (kgm²) 0.125 Motor weight (kg) 205
Maximum mechanical speed
nmax(min-1)
4300
(6000)*
Sound Pressure level (db(A))
at 50 Hz 74
D-End Bearing 6310
2RSC3 N-End bearing 6310
2RSC3
Vibration Class A Mounting IM1001
Insulation class H Temperature rise Class F
Motor Nominal voltage (V) 400 Thermal Protection PTC 140°C
* On request
|