Smoke & Heat Extract Fans KVB/F
12Pages

{{requestButtons}}

Catalog excerpts

Smoke & Heat Extract Fans KVB/F - 1

Box Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Curtains and Heating Products | Tunnel Fans Smoke & Heat Exhaust Fans KVB/F

Open the catalog to page 1
Smoke & Heat Extract Fans KVB/F - 2

© Systemair 2013. Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com The catalogues published by SYSTEMAIR are reviewed and amended whenever necessary and any such modifications are made in new editions. The catalogue edition is printed on the inside back cover and the user is responsible for using the latest edition. Please visit our website at http://www.systemair.com The characteristics of the equipment described in this catalogue (e.g., sizes, features, etc.) may be modified without prior notice.

Open the catalog to page 2
Smoke & Heat Extract Fans KVB/F - 3

Disclose the secret of fresh air! Systemair has been taking care of Indoor Air Quality (IAQ) as an essential resource since 1974. Today Systemair is one of the leading ventilation companies worldwide. A success story, which started in Skinnskatteberg, Sweden with the invention of the inline duct fan. This invention revolutionised the ventilation world. Since then the company has continuously advanced and now offers a comprehensive range of products for all ventilation requirements. The expert at Systemair have the required knowledge and understanding in finding solutions when considering...

Open the catalog to page 3
Smoke & Heat Extract Fans KVB/F - 4

KVB/F • entilation fan tested according V EN 12101-3 for 400ºC/2h and certified by BSI. • elt driven fan with motor out of the B airstream. • orward curved double inlet galvanized F steel impeller. • alvanized steel single skin box. G • P 55, B3, F Classe Three phase IEC I Motor. • nline operation. I • ith single or two speed motors. W The KVB/F range covers airflows from 1000 to 50000 m3/h, for indoor and outdoor installation, with motor located outside of the risk area. Accessories Outlet hood, roof, isolator. Applications: Industrial kitchen extract, malls, cinemas, theaters, garages...

Open the catalog to page 4
Smoke & Heat Extract Fans KVB/F - 5

SMOKE & HEAT EXHAUST FANS | 5

Open the catalog to page 5
Smoke & Heat Extract Fans KVB/F - 6

Dimensions KVB/F 6 | SMOKE & HEAT EXHAUST FANS

Open the catalog to page 6
Smoke & Heat Extract Fans KVB/F - 7

Selection Curves KVB/F 10-10 Not usable Not recommended Not recommended Not usable Not recommended Not recommended Not usable Not recommended Not recommended V(m /h) 1000 C2 (m/s) 3 Not usable Not recommended Not recommended V(m /h) 1500 C2 (m/s) 3 SMOKE & HEAT EXHAUST FANS | 7

Open the catalog to page 7
Smoke & Heat Extract Fans KVB/F - 8

Selection Curves KVB/F 20-20 NotUTILIZABLE NO usable Not recommended UTILIZABLE SEGUN SERIE NO recommended NotRECOMENDADO Not usable Not recommended Not recommended V(m /h) 2000 C2 (m/s) Not usable NO UTILIZABLE UTILIZABLE SEGUN SERIE Not recommended NO RECOMENDADO Not recommended NotUTILIZABLE NO usable Not recommended UTILIZABLE SEGUN SERIE NO recommended NotRECOMENDADO 2000 C2 (m/s) pd (mm H2O) 8 | SMOKE & HEAT EXHAUST FANS

Open the catalog to page 8
Smoke & Heat Extract Fans KVB/F - 9

Selection Curves KVB/F 30-28 120 110 Not usable Not recommended Not recommended 5000 C2 (m/s) 2 pd (mm H2O) NO UTILIZABLE UTILIZABLE SEGUN SERIE NO RECOMENDADO Note: All these fan curve are for 50 Hz. For 60 Hz the transmission will be adjusted to the working point. SMOKE & HEAT EXHAUST FANS | 9

Open the catalog to page 9
Smoke & Heat Extract Fans KVB/F - 10

Specification text KVB/F smoke extract box fan range, tested at LGAI: Barcelona in accordance with EN 12101-3 for 400°C/2h and certified by BSI for inline operation. Belt driven with motor out of the airstream. MOtor IP 55, insulation class F. Forward curved double inlet galvanized steel impeller. Galvanized steel, single skin panels. With single or two speed motors. Airflows from 1.000 to 50.000 m3/h. For indoor and outdoor installation (with roof cover). KVB/F 3D Model Below some pictures how looks an example of KVB/F unit in 3D, in the soft version catalogue for web you also can move and...

Open the catalog to page 10
Smoke & Heat Extract Fans KVB/F - 11

Iri compliance with the Directive 8&'106/EEC of the Council of European Communities of 21 December 1986 on the approbation of laws, regulations and administrative provisions of the Member States relating to the construction products {Construction Products Directive - CPD). amended by the Directive 93/68/EEC ot the Council of European Communities of 22 July 1993, It has been stated that the construction product Powered Smoke and Heat Exhaust Ventilators for use as detailed on the Supplementary information Sheet Systemair HVAC Spain S.L.U. C/Montecarlo, 14, 28942 Fuenlabrada (Madrid), and...

Open the catalog to page 11
Smoke & Heat Extract Fans KVB/F - 12

Systemair HVAC Spain S.L.U. C/Montecarlo, 14 28942 Fuenlabrada (Madrid) - Spain Fax: +34 91 600 29 08 general@systemair.es www.systemair.es

Open the catalog to page 12

All Systemair catalogs and technical brochures

  1. DELTRI+

    8 Pages

  2. SYSAQUA R32

    7 Pages

  3. Topvex

    134 Pages

  4. Topvex range

    8 Pages

  5. MoJet

    6 Pages

  6. prioJet EC

    4 Pages

  7. Roof fan TFC

    4 Pages

  8. Axial fans

    48 Pages

  9. Chilled Beam

    4 Pages

  10. EC-Fans

    24 Pages

  11. Roof Fans DVG

    12 Pages

  12. MRT Catalogue

    28 Pages

  13. Box Fans 2013

    20 Pages

  14. ATEX-Fans

    2 Pages

  15. Fan Catalogue

    403 Pages

  16. AXC-Box

    2 Pages

Archived catalogs

  1. KDRE/KDRD

    8 Pages

  2. Axial Fans

    40 Pages

  3. Iris Damper

    4 Pages

  4. Air Curtains

    6 Pages