Systemair fans and Directive ErP 125 Globally increasing electricity consumption automatically increases the production of CO2 released into the atmosphere. The excess content of CO2 in the air has a negatively impact on our planet's climate. The Kyoto Protocol was and still is designed to curb this. It is an agreement adopted and signed by the European Union in 1997. The main aim of the protocol is to decrease CO2 emissions by 20 % by the year 2020. Since electric motors consume 30-40 % of the electricity produced worldwide, this is an obvious area with the greatest potential for achieving...

Open the catalog to page 2
ErP Guideline 2013 - 3

Directive ErP 125 | The first phase of the timetable began on 16.06.2011 and it was the reason for adding names of certain Systemair fans by including the index IE2. The first phase concerns electric motors with an output range of 0.75 kW to 375 kW. The main technical difference besides higher efficiency IE2 is the option of controlling revolutions only by means of a frequency converter and built-in thermistors as sensors assessing overheating of motors. In the second stage, i.e. from 01.01.2015, IE3 efficiency shall be required for motors within the output range of 7.5 kW to 375 kW,...

Open the catalog to page 3
ErP Guideline 2013 - 4

Systemair and European Legislation As opposed to this, a similar type of fan, the KVKE 315EC, is fully capable of complying with EC requirements for 2015 as well. The minimum target efficiency of this type of fan is at 42.1 % for 2013, and 45.1 % for 2015. The high efficiency 50.1 % of the fan KVKE 315EC is given by using an electronically commutated motor, which is outstanding for its very high efficiency. Its efficiency is even higher than the current international efficiency IE3. EC fans have efficiency at the classification level IE4, which is defined only in the new standard of the...

Open the catalog to page 4
ErP Guideline 2013 - 5

Graph 1: Power output characteristics of the fan KVKE 315L Graph 2: Power output characteristics of the fan KVKE 315EC In the same manner, Systemair assessed all types of fans and decided on their needed modifications. In many cases replacement has occurred, and shall continue with regard to the second phase of the timetable in 2015, of the existing fan wheel for a more efficient wheel, which shall increase the overall efficiency. The second possibility was and shall be replacement of the existing asynchronous fan motors for modern brushless EC motors, which shall again increase their...

Open the catalog to page 5
ErP Guideline 2013 - 6

| Systemair products and directive ErP 125 RVK sileo 250E2-L RVK sileo 250E2-XL RVK sileo 315E2

Open the catalog to page 6
ErP Guideline 2013 - 7

Systemair products and directive ErP 125 | RVK sileo 125E2-L RVK sileo 150E2 RVK sileo 150E2-L RVK sileo 160E2 RVK sileo 160E2-L RVK sileo 200E2 RVK sileo 200E2-L RVK sileo 250E2 RVK sileo 250E2-L RVK sileo 250E2-XL RVK sileo 315E2 KVKE 125 KVKE 160 KVKE 200 KVKE 250M KVKE 250L KVKE 315M KVKE 315L no replacement no replacement no replacement

Open the catalog to page 7
ErP Guideline 2013 - 8

| Systemair products and directive ErP 125

Open the catalog to page 8
ErP Guideline 2013 - 9

Systemair products and directive ErP 125 |

Open the catalog to page 9
ErP Guideline 2013 - 10

| Systemair products and directive ErP 125 KDRE 45 KDRE 50 KDRD 50 KDRE 55 KDRD 55 KDRE 65 KDRD 65 KDRD 70 TFSR 125M TFSR 125XL TFSR 160 TFSR 200 TFSR 315M TFSR 315L TFSK 125M TFSK 125XL TFSK 160 TFSK 200 TFSK 315M TFSK 315L

Open the catalog to page 10
ErP Guideline 2013 - 11

Systemair products and directive ErP 125 | DVS 190EZ DVS 225EV DVS 225EZ DVS 310ES DVS 310EV DVS 311ES DVS 311EV DVS 355DV DVS 355E4 DVS 355DS DVS 355E6 DVS sileo 400DS DVS sileo 400DV DVS sileo 400E4 DVS sileo 400E6 DVS sileo 450DV DVS sileo 450E4 DVS sileo 450E6 DVS sileo 499DV DVS sileo 500DS DVS sileo 500DV DVS 500E4 DVS sileo 500E6 DVS sileo 560DS DVS sileo 560DV DVS sileo 630DS DVS sileo 630DV DVS 710D6-L DVS 710DS DHS 190EZ DHS 225EV DHS 225EZ DHS 310ES DHS 310EV DHS 311ES DHS 311EV DHS 355DV DHS 355E4 DHS 355DS DHS sileo 400DS DHS sileo 400DV DHS sileo 400E4 DHS sileo 400E6 DHS...

Open the catalog to page 11
ErP Guideline 2013 - 12

| Systemair products and directive ErP 125 DVSI 190EZ DVSI 225EV DVSI 225EZ DVSI 310ES DVSI 310EV DVSI 311ES DVSI 311EV DVSI 355DV DVSI 355E4 DVSI 355DS DVSI sileo 400DS DVSI sileo 400DV DVSI sileo 400E4 DVSI sileo 400E6 DVSI sileo 450DV DVSI sileo 450E4 DVSI sileo 450E6 DVSI sileo 499DV DVSI sileo 500DS DVSI sileo 500DV DVSI sileo 500E6 DVSI sileo 560DS DVSI sileo 560DV DVSI sileo 630DS DVSI sileo 630DV DVSI 710D6-L DVSI 710DS DHA sileo 400DV DHA sileo 400E4 DHA sileo 500DV DHA sileo 500E4 DHA sileo 630DS DHA sileo 630DV DHA sileo 630E6 Category Category Category Category Category Category...

Open the catalog to page 12
ErP Guideline 2013 - 13

Systemair products and directive ErP 125 | AW sileo 200E2 AW sileo 200E4 AW sileo 250E2 AW sileo 250E4 AW sileo 300E4 AW sileo 315DV AW sileo 315E4 AW sileo 350DV AW sileo 350E4 AW sileo 400DV AW sileo 400E4 AW sileo 450DV-K AW sileo 450DV AW sileo 450E4-K AW sileo 450E4 AW sileo 500DV AW sileo 500E4 AW sileo 560DV AW sileo 560E4 AW sileo 630DS AW sileo 630DV AW sileo 630E6 AW sileo 710DS AW sileo 710DV AW sileo 710E6 AW sileo 800DS AW sileo 910DS AW sileo 1000DS AW 300E2-K AW 1000DS-L

Open the catalog to page 13
ErP Guideline 2013 - 14

| Systemair products and directive ErP 125 AR sileo 200E2 AR sileo 200E4 AR sileo 250E2 AR sileo 250E4 AR 300E2-K AR sileo 300E4 AR sileo 315DV AR sileo 315E4 AR sileo 350DV AR sileo 350E4 AR sileo 400DV AR sileo 400E4 AR sileo 450DV-K AR sileo 450DV AR sileo 450E4-K AR sileo 450E4 AR sileo 500DV AR sileo 500E4 AR sileo 560DV AR sileo 560E4 AR sileo 630DS AR sileo 630DV AR sileo 630E6 AR sileo 710DS AR sileo 710DV AR sileo 710E6 AR sileo 800DS AR sileo 910DS AR sileo 1000DS AR 1000DS-L CE 140 S-125 CE 140 M-125 CE 140 L-125 CE 140 S-160 CE 140 M-160 CE 140 L-160 CE 200-4 CE 225-4 CE 250-4...

Open the catalog to page 14
ErP Guideline 2013 - 15

Systemair products and directive ErP 125 | Category Category Category Category Category Category Category Category Category Category MUB/F KBR/F DVG / DVG-EC DVV/F WVI / WVA AXC(F) / AXC(B) Category Category Acid-resistant Acid-resistant Category Category Category Category Category Category Category Category RVK-EX KTEX AW-EX EX DVEX / DVV-EX DKEX AXC-EX PRF-EX no replacement no replacement no replacement no replacement no replacement no replacement

Open the catalog to page 15

All Systemair catalogs and technical brochures

  1. DELTRI+

    8 Pages

  2. SYSAQUA R32

    7 Pages

  3. Topvex

    134 Pages

  4. Topvex range

    8 Pages

  5. MoJet

    6 Pages

  6. prioJet EC

    4 Pages

  7. Roof fan TFC

    4 Pages

  8. Axial fans

    48 Pages

  9. Chilled Beam

    4 Pages

  10. EC-Fans

    24 Pages

  11. Roof Fans DVG

    12 Pages

  12. MRT Catalogue

    28 Pages

  13. Box Fans 2013

    20 Pages

  14. ATEX-Fans

    2 Pages

  15. Fan Catalogue

    403 Pages

  16. AXC-Box

    2 Pages

Archived catalogs

  1. KDRE/KDRD

    8 Pages

  2. Axial Fans

    40 Pages

  3. Iris Damper

    4 Pages

  4. Air Curtains

    6 Pages