Cassette chilled beam - 1

Cooling effects for Stratus 66 and 126 Cassette chilled beam Pressure Drop (kPa) and water ow at 0,05 l/s Cooling capacity Water (W) at Tmean Cooling capacity Primary air (W) at TPr Stratus is a cassette chilled beam and integrates ventilation, cooling and heating. It covers a wide range of supply air and assures you the best room comfort. It is supported with a nozzle technology NCS (Noz- ing the air so it will create low air velocities in the occupied zone. Stratus is available in sizes 600 x 600 mm and 1200 x 600 mm and adapted to false ceilings with a module of 600 mm. zle Control System) that gives you the highest induction rate and exible air pattern. Together with RCS (Room Comfort Support), it helps you to have a good indoor condition by direct- Unit size Nozzle setting • Cassette chilled beam for integrating in suspended ceiling • Available with the functions for comfort control and control equipment • Suited for standard 600 mm ceiling module • Available in two sizes, 600x600 mm and 1200x600 mm. Unit size Nozzle setting Cooling capacity Primary air (W) at TPr 6 Pressure Drop (kPa) and water ow at 0,05 l/s Cooling capacity Water (W) at Tmean 10 PW (kPa): Water pressure drop Room temperature Ceiling room temperature Denitions Tmean (K): Is the Temperature difference between mean water (cooling/heating in and out) and room air TR TPr (K): Temperature difference between room air TR and primary air TPr Temperature difference between water ow TWIN and return TWOUT TSWIN (K): Temperature difference between ceiling room air Tt and inlet water TWIN PPr (Pa): Primary air pressure drop TWIN (ºC): Water inlet temperature TWOUT (ºC): Water return temperature TPr (ºC): Primary air cooling capacity Water cooling capacity S = small M = medium L = large Ptotal (W): Total cooling capacity PPr + PSW QW (l/s): Water volume ow rate Primary air volume ow rate Sound power level 3

Open the catalog to page 1
Cassette chilled beam - 2

Flow patterns, sound data, corrections, pressure drop Heating effects for Stratus 66 and 126 Unit size Nozzle setting Pw Water Pressure Drop (kPa) and water ow at 0,015 l/s Heating Capacity Water Air (W) at Tmean 5 Unit size Nozzle setting The sound power levels for each octave band are obtained by adding the sound pressure level LA10, dB(A) to the corrections Koct given in the table above, according to the following formula: LW = LA10 + Koct. Correction Koct, dB Octave band, middle frequency (Hz) Pw Water Pressure Drop (kPa) and water ow at 0,015 l/s Heating Capacity Water Air (W) at Tmean...

Open the catalog to page 2
Cassette chilled beam - 3

RCS (Room Comfort Support) With the use of RCS, you avoid the risk of getting a draft in the occupied zone and with an unhealthy workplace. To arrange the vanes in a pattern when beams have a risk to collide, are easily done and doesn’t affect pressure drop or noise level. NCS (Nozzle Control System) With the possibility to select a range of nozzle position that suits your installation. You will be able to adjust to the desired supply airow by selecting Nozzle positions L (Low), M (Mid) and H (for higher capacities by combining Low and Mid nozzles). Following possibilities can provide you...

Open the catalog to page 3
Cassette chilled beam - 4

Fans | Air Handling Units | Air Distribution Products | Fire Safety | Air Curtains and Heating Products | Tunnel Fans Systemair • Inhouse studio • 2011 • Art no E80XX Cassette chilled beam

Open the catalog to page 4

All Systemair catalogs and technical brochures

  1. DELTRI+

    8 Pages

  2. SYSAQUA R32

    7 Pages

  3. Topvex

    134 Pages

  4. Topvex range

    8 Pages

  5. MoJet

    6 Pages

  6. prioJet EC

    4 Pages

  7. Roof fan TFC

    4 Pages

  8. Axial fans

    48 Pages

  9. Chilled Beam

    4 Pages

  10. EC-Fans

    24 Pages

  11. Roof Fans DVG

    12 Pages

  12. MRT Catalogue

    28 Pages

  13. Box Fans 2013

    20 Pages

  14. ATEX-Fans

    2 Pages

  15. Fan Catalogue

    403 Pages

  16. AXC-Box

    2 Pages

Archived catalogs

  1. KDRE/KDRD

    8 Pages

  2. Axial Fans

    40 Pages

  3. Iris Damper

    4 Pages

  4. Air Curtains

    6 Pages