deltaflow Series Models
DF 8 DF 10 DF 25
Pipe diameter 3-25 mm 15 – 100 mm 65 –3000 mm Media • Gas• Gas• Gas• Liquid• Liquid• Liquid
• Steam • Steam • Water-laden gas Pressure range 0 – 690 bar 0 – 690 bar 0 – 250 bar Installation •Weld-in, flange, •Weld-in, flange, • For gas applications: from or screw-in or screw-in above with slight decline
sampling lengthsampling lengthtoward point of probe.•For liquid applications: over-head or with slight incline
toward point of probe Accreditations • Eex• Eex•Eex• High pressure• High pressure •Emission quantity measure-
• PED97/34/EG• PED97/23/EG ment per §13 and 17 of theof the Federal Emission Control Ordinance Precision • Better than 1% of the measured value Sampling range Options • To >1:30, bi-directional • Integrated pressure and
industrial temperature sensors• Weather-proof casing for harsh outdoor applications Temperature range • -200 – 1240 °C Materials Metering Connections • Carbon steel (studs only)• 1.4571 (standard)
• 1.4828 (high temperature)
• 1.4539, Hastelloy C4, Haynes Alloy (oxidizing media)
• 15 Mo 3, 10 CrMo 9 10, 13 CrMo 44, X20 CrMoV 12 1, P91 (boiler steels)
• Additional materials available on request • Threaded screw or weld-in connection• Cutting or clamping ring threaded connection
• Shut-off valve,
industrial ball valve,
slide valve
• Mounting block with three-way or five-way manifolds for direct transmitter install >
6
a • Steam slider valve and condensation
industrial containers (for steam applications)
• High-pressure shut-off valves, single or double
• Other connections available on request Material Certifications • 3.1a / 3.1b / 2.2 >