Catalogue Basics and equations of dp-flow-measurement
www.systec-controls.de
print switch display
Page / 9
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
systec Controls - 158035
/ 9
See other catalogues for systec Controls
Text version of the page
Pressure p in Pa
atm
1 atm = 101,325 Pa
mWS
1 mWS = 9806.65 Pa
mmWS
1 mmWS = 9.80665 Pa
mmHG
1 mmHG = 133.322 Pa
psi (lbf/in2)
1 psi = 6,894.76 Pa
Welcome to systec Controls
The deltaflow dynamic pressure probe you have purchased is a highly precise measurement tool of superior quality. You can count on it for the very best performance even under the most adverse conditions.
Accurate evaluation of all measurements and precise calculation of flow are integral factors contributing to the high degree of precision.
This booklet contains all information you will need in order to achieve optimal measurement results with your deltaflow.
In this booklet, the pressure unit should always be interpreted as absolute pressure (index abs). If gauge pressure values are the only values which are available (index u or g), then the current or average ambient pressure at the sampling site must be added. The average ambient pressure at sea level is 101,325Pa.
Temperature T in K
Unit
SI Unit K
°C
K=°C+273.15
°F
K=((°F-32)*5/9) + 273.1 5
Table of Contents
Differential Pressure dp in Pa
Unit
SI Unit Pa
hPa
1hPa = 100 Pa
kPa
1kPa = 1,000 Pa
mbar
1mbar = 100 Pa
bar
1bar = 100,000 Pa
mWS
1 mWS = 9806.65 Pa
mmWS
1 mmWS = 9.80665 Pa
mmHG
1 mmHG = 133.322 Pa
psi (lbf/in2)
1 psi = 6,894.76 Pa
Welcome to systec Controls........................................2
Table of Contents.......................................................2
Basics / Units of Measurement....................................2
General Basic Calculation Information.........................3
Formula Symbol..................................................3
Resistance Coefficient.................................................3
Expansion Number e..................................................3
Conduit Interior Diameter Conduit d...........................4
Measured Differential Pressure dp..............................4
Current Operational Density pb................................4
Simplified Calculation Equations.................................6
Converting the Mass Flow to Other Units....................6
flowcom Flow calculator............................................7
Questions?.................................................................7
Appendix...................................................................8
Mass Flow qm in kg/s
Unit
SI Unit kg/s
t/d
1 t/d = 1,000/86,400 kg/s
t/h
1 Vh = 1,000/3,600 kg/s
t/min
1 t/min = 1,000/60 kg/s
t/s
1 t/s = 1,000 kg/s
kg/h
1 kg/h = 1/3,600 kg/s
kg/min
1 kg/min = 1/60 kg/s
lb/d
1 lb/d = 5.249911*10e-6 kg/s
lb/h
1 lb/h = 125.99786*10e-6 kg/s
lb/min
1 lb/min = 7.5598*10e-3 kg/s
lb/s
1 lb/s = 0,45359237 kg/s
Basics / Units of Measurement
All units of measurement used in this booklet are SI units. If you use a different unit system, we recommend that you convert your values to SI units before performing calculations and then afterwards convert them back to the unit system you are using.
Instructions for converting the mass flow into volume flow, standard volume flow, or speed are described later in this booklet.
Pressure p in Pa
Unit
SI Unit Pa
hPa
1hPa = 100 Pa
kPa
1kPa = 1,000 Pa
MPa
1Mpa = 1,000,000 Pa
mbar
1mbar = 100 Pa
bar
1bar = 100,000 Pa
Torr
1 Torr = 133.3224 Pa
at
1 at = 98,066.65 Pa
Diameter d in m
Unit
SI Unit m
mm
1 mm = 0.001 m
cm
1 cm = 0.01 m
ft
1 ft = 0.3048 m
in
1 in = 0.0254 m
deltaflow Basic Calculation Information 07/03
Page 2
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
pdf-page pdf di En 2008-12-49-02