Company C > Products P > Technology T > Application A >
Open the catalog to page 1Illustrations simplified, schematically drawn and not to scale. Product type Manifold nozzle sliding fit Replaceable threaded tipsAvailable with seven Controlled Vestige (CV) tip options including valve gates for zero vestige applications. See table at right.Available gating types > D Dt Gate Cone point Valve gate: VG12E Diametric gate VG12S & VG23S Straight gate VG-12EGate: > Major Dimensions (mm) Heating > J Z 8 Dؘ27 Dt7 > Available tip styles for SR8 Nozzles Gating of nozzle tip Cone point thermal gate > Valve Gate 4 5 8 CV-11Gate: VG-12SGate: ؘ1.0 - 2.4Dt:7 ؘ 1. - 2.4Dt:7 ؘ2.4Dt:7 thermocouple...
Open the catalog to page 2Illustrations simplified, schematically drawn and not to scale. 1. Cut out for the nozzle 2. Cut out for connections3. Alignment pin 1 > * drawn offset** to all other pocket surfaces 1.6 1.6 H7 34 ؘ27 20 K-5 electrical power thermocouple 2 > 75 The alignment pin prevents the nozzle from rotating. > H7 4 3 > 11 4. Cut out for the nozzle tip DtHA)b) Tip Hot runner gate ؘThrough bore nozzle tip (CV11, CV11D, CV11E, VG12S and VG12EBlind bore nozzle tip (CV21 & VG23S) Length from back of cavity plate toGate locationGeneral tolerances:Surfaces:Values of the dimension J can be found in the data sheet...
Open the catalog to page 3tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:15.00pt "Arial", sans-serif; } .font4 { font:25.00pt "Arial", sans-serif; } .font5 { font:17.00pt "Times New Roman", serif; } Rynventive Sries SR^|c|^Manifold intgration HlA olding solutions Illustrations simplified, schematically drawn and not to scale. SR8 S驩ries SR8 manifold criteria: -*SR8hotrunner Systems typically have a clearance between the thrust pads and the mold plates in the cold condition....
Open the catalog to page 4Illustrations simplified, schematically drawn and not to scale. L SR8 CV11D > K General: Filled and unfilled materials > 12 More heat in gate area for semi-crystalline materials > H7 One heater operation for independent nozzle control. > ؘ34 27 Long life replaceable heater and thermocouple. > Gate vestige remains below the part surface for unfilled materials. Same as CB CV11 but with dimple. > LkJ Z Lk is used to confirm the correct depth of the 90 > Information regarding ذ angle. Lk is the distance from support ring shoulder to a precision > H7 tolerances and surfaces 12mm ball. > shape and...
Open the catalog to page 6Illustrations simplified, schematically drawn and not to scale. L SR8 CV11E > K General: Filled and unfilled materials > 12 One heater operation for independent nozzle control. > H7 Long life replaceable heater and thermocouple. > ؘ34 27 Tip extension for gating on part contours. > 2.1 Min LkJ F(10 Max) Z Lk is used to confirm the correct depth of the 90 > Information regarding ذ angle. Lk is the distance from support ring shoulder to a precision > Orifice tolerances and surfaces 12mm ball. > shape and position tolerances cut out for connections 30 groove/bore for locking pinplease see page 2谓Cut...
Open the catalog to page 7Illustrations simplified, schematically drawn and not to scale. L SR8 VG12E > K General: Filled and unfilled materials > 12 Pneumatic or hydraulic actuation One heater operation for independent nozzle control. > H7 ؘ34 Long life replaceable heater and thermocouple. > 27 Straight valve pin in gate. > Tip extension for gating on part contours. > LkJ Z Lk is used to confirm the correct depth of the 90 > Information regarding ذ angle. Lk is the distance from support ring shoulder to a precision > tolerances and surfaces 12mm ball. > H7 H7 shape and position tolerances cut out for connections 7 蘘2.4...
Open the catalog to page 9Illustrations simplified, schematically drawn and not to scale. L SR8 VG12S > K Filled and unfilled materials > 12 Pneumatic or hydraulic actuation One heater operation for independent nozzle control. > H7 ؘ34 Long life replaceable heater and thermocouple. > 27 Straight valve pin in gate. 2.4 > Lk J Z Lk is used to confirm the correct depth of the 90 > Information regarding ذ angle. Lk is the distance from support ring shoulder to a precision > H7 tolerances and surfaces 12mm ball. > shape and position tolerances 7 cut out for connections groove/bore for locking pinplease see page 2蘓Cut out in...
Open the catalog to page 10Illustrations simplified, schematically drawn and not to scale. Illustrations simplified, schematically drawn and not to scale. Illustrations simplified, schematically drawn and not to scale.Illustrations simplified, schematically drawn and not to scale. Illustrations simplified, schematically drawn and not to scale. Illustrations simplified, schematically drawn and not to scale. L SR8 VG23S > K General: Filled and unfilled materials > 25 Pneumatic or hydraulic actuation One heater operation for independent nozzle control. > H7 ؘ34 Long life replaceable heater and thermocouple. > 27 Straight...
Open the catalog to page 114 Pages
4 Pages
12 Pages
20 Pages
7 Pages
5 Pages
6 Pages
6 Pages
45 Pages
6 Pages
6 Pages
6 Pages
34 Pages
17 Pages
16 Pages
16 Pages
17 Pages
16 Pages
16 Pages
14 Pages
14 Pages
22 Pages
12 Pages
15 Pages
17 Pages
6 Pages
17 Pages
17 Pages
20 Pages
21 Pages
13 Pages