Trace Hydrogen (H2) P/N 701 - Synkera Technologies - #1

/ 2


catalogue search
Trace Hydrogen (H2) P/N 701 - Synkera Technologies
P. 01
Trace Hydrogen (H2) P/N 701 - Synkera Technologies
P. 02
Pages:
Trace Hydrogen (H2) P/N 701 - Synkera Technologies


See other catalogues for Synkera Technologies

Text version of the page
Synkera Technologies, Inc. 2021 Miller Dr., Suite B Longmont, CO 80501
Trace Hydrogen Sensor (P/N 701)
SENSOR FEATURES:
• High sensitivity to low hydrogen concentrations (10 — 1000 ppm)
• Fast response time (15 seconds at 100 ppm)
• Environmental temperature range of —20 to 50°C
• Environmental humidity range of 0 to 90% RH, non-condensing
• Low dependence on flow rate
Sensor Response Characteristics
The figures below show typical response and selectivity data for sensors operated in clean, dry gas.
1
1.00E+07
to
S
-10 ppm
-25 ppm 50 ppm
100 ppm
500 ppm
1000 ppm
1.00E+06
to to CD
1.00E+05
1.00E+04
300 600 900 Time (seconds)
1200
0
Sensor resistance upon exposure to varying concentrations of H2. Air applied for 300 seconds, then H2 in air for 300 seconds, followed by air.
Electrical Characteristics
The electrical properties below are typical for Trace Hydrogen Sensors. If the actual values differ the customer will be notified with the shipment. Circuits are available that will be preset to the correct values.
Property
Symbol
Value
Remarks
Heater Power Consumption
Ph
~ 600 mW
At Vh = 5.4
Heater Voltage
Vh
5.4 VDC
Tsensor ~240°C
Heater Resistance
Rh
32O ± 2 O
At room temperature
Sensing Voltage
Vc
5.0 VDC
Recommended
720-494-8401 e-mail: info@synkera.com
www.synkera.com 720-494-8402 (fax
• For information on warranty, please refer to Synkera Technologies, Inc. Standard Terms and Conditions.
• Information on this data sheet represents typical values from a number of Synkera sensors. Actual values from sensor to sensor can vary slightly.

pageCatalog pdf di En 2012-02-07-16