Features
” All-welded design provides reliable containment of system
fluid.
” Forward flow starts at less than 2 psig (0.14 bar) pressure
differential.
” Valve closes with less than 2 psig (0.14 bar) back pressure.
” 316L SS body offers enhanced material purity.
” Choice of standard or high-purity wetted surface finishes.
” Processing in accordance with Swagelok® Ultrahigh-Purity
Process Specification (SC-01) is available.
” Tube butt weld, female VCR® fitting, integral male VCR
fitting, rotatable male VCR fitting, and Swagelok tube fitting
end connections are available.
Materials of Construction
All components are wetted.
. Bodies with tube butt weld ends are 316L VAR SS/SEMI F200305 High-
Purity, 20 % minimum elongation allowed.
. Aflas®, Buna N, ethylene propylene, and neoprene also available; see
Options.
. Material Safety Data Sheet for bonding agent available on request.
2
3
4
1
Al l -Welded Check Valves
CW Ser ies
Component Material Grade/ASTM Specification
1 Body 316L SS/A479.
2 Poppet Fluorocarbon FKM.-bonded. 316 SS/A479
3 Guidance wafer Alloy X-750/B637
4 Poppet stop 316L SS/A240
Technical Data
Cracking
Pressure
psi (bar)
Maximum
Back
Pressure
psig (bar)
Maximum
Pressure
Drop
psi (bar)
Minimum
Burst
Pressure at
70°F (20°C)
psig (bar)
Flow
Coefficients
(Cv)
Less than
2 (0.14)
Full
pressure
rating
145
(10.0)
12 000
(826)
0.55
(1/4 in., 6 mm
Swagelok tube
fitting and tube
butt weld ends)
0.70
(1/4 and 1/2 in.
VCR fittings, 3/8
and 1/2 in. tube
butt weld ends)
Pressure-Temperature Ratings
Material Name 316L SS
Temperature
°F (°C)
Working Pressure
psig (bar)
10 (23) to 100 (37)
200 (93)
300 (148)
400 (204)
3000 (206)
2530 (174)
2270 (156)
2065 (142)
Flow Data at 70°F (20°C)
Pressure
Drop
psi (bar)
Air Flow
std ft3/min (std L/min)
0.55 Cv 0.70 Cv
10 (0.68) 6.2 (170) 7.9 (220)
50 (3.4) 16 (450) 21 (590)
100 (6.8) 29 (820) 37 (1040)
š® For valves not actuated for a period of time, initial
cracking pressure may be higher than the set
cracking pressure.
š® Check valves are designed for directional flow
control only. Swagelok check valves should never be