SunKaier's Sanitary Magnetic Mixer is designed for hygienic and aseptic mixing applications. It features a weld plate and a mixer unit with a gear drive, utilizing sliding bearings made from Silicone Carbide for durability in wet environments.

Specifications
  • Product wetted surface finish: Ra < 0.5 μm (20 μinch), with options for mechanical and electro polishing.
  • Working pressure: -1 to 7 bar (g) (-15 to 100 psig).
  • Mixing speed: 10 – 600 rpm; CIP max 50 rpm; SIP 0 rpm.
  • Temperature range: max 90°C (194°F) for product mixing, max 95°C (203°F) for CIP, max 150°C (302°F) for SIP.
  • Power & Weight: SKM001 - 0.37 kw (0.5 hp), 12 kg (27 lb); SKM002 - 1.1 kw (1.5 hp), 30 kg (66 lb).
  • Voltage and frequency: 380V, 50Hz; 240/120V, 48-62Hz.
  • Protection class: IP66 for AC motors and VFD stand-alone, IP20 for VFD enclosure unit.

Materials
  • Impeller and Weld Plate: AISI 316L.
  • Drive rotor and distance piece: AISI 316L.
  • Male Bearing: Zirconia.
  • Male Bearing Gasket: ISOLAST 9501 (Perfluro Elastomer).
  • Female Bearing: Silicone Carbide.
  • Gearbox oil: USDA-H1.

Installation & Caution
  • Ensure proper welding of the tank plate to avoid distortion and damage.
  • Secure the male bearing with the correct torque to prevent vibration and potential cracking.
  • Carefully install the mixing head to avoid impact damage to the bearings.
  • Do not operate the mixer when dry to prevent overheating and wear.
  • Use attractor tools when moving mobile tanks to secure the mixing head and prevent damage.
  • Avoid mixing solutions with insoluble, hard, and abrasive solids to prevent bearing damage.

Recommendations
Follow the Installation and User Guide for detailed procedures and maintenance to ensure optimal performance and longevity of the SunKaier Magnetic Mixer.
See more

Catalog excerpts

Magnetic mixer/Sanimag Mixer/Application for the hygienic and aseptic-1

SANIMAG MIXER 【Sanitary Magnetic Mixer】 SunKaier LLC, USA 3422 Old Capitol Trail Ste 1494 Wilmington DE 19080 Tel.: 1-302-295-0960 Fax: 1-302-295-0827 [email protected] www.sunkaier.com SUNKAIER CHINA SUNKAIER CHINA Kunshan, Jiangsu, China. Tel.: 0086 512 57599868 Fax: 0086 512 50316682 www.sunkaier.cn

 Open the catalog to page 1
Magnetic mixer/Sanimag Mixer/Application for the hygienic and aseptic-2

Sunkaier Magnetic Mixer Installation & Caution Sunkaier magnetic mixer consists of a weld plate and a mixer unit including gear drive. The static Welding of the tank plate male bearing is secured to the vessel's tank plate and the rotating female bearing is integrated and When welding the tank plate into the tank, specific procedures must be followed to prevent excessive distortion of the tank plate due to sealed into the mixing head, or rotor, of the mixer. overheating. If the concentricity of the tank plate is out of specification, the mixing head and/or the outer driving head of the drive...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.