SWITCHBOARD METERS - Storage Battery Systems, Inc - #1

/ 1


catalogue search
SWITCHBOARD METERS - Storage Battery Systems, Inc
P. 01
Page:
SWITCHBOARD METERS - Storage Battery Systems, Inc


See other catalogues for Storage Battery Systems, Inc

Text version of the page
34 Specifications Battery Input 90 to 180 VDC, 3VA - For 125V battery Ground Resistors 30K ħ1% from each bus to ground Voltage Indication 0 to ħ199.9 VDC in 0.6” bright red LED digit and decimal point accuracy is ħ0.2 VDC Ranges Ħ +Bus to Ground (+GND) Ħ -Bus to Ground (- to GND) Ħ Ground Fault Voltage (Fault) Ħ Battery Voltage (BAT) Scanning Each range is automatically scanned and read every three seconds. Alarms Ħ The “+/- Fault” relay energizes and latches when the + fault voltage exceeds the +/- set value for the time setting. The “alarm” LED lights. Set range is 13.0 to 100.0V Ħ “Hi Battery” and “Low Battery” relays energize and latch when the battery voltage exceeds the “Hi” or “Low” set value for the time setting. (“Hi” set range is 125.0 to 150.0V, and the “Low” set range is 100.0 to 125.0V) BATTERY MONITORING EQUIPMENT Portable Battery Monitor / Ground Fault Locator Voltage/Ground Meter/Alarm Relays Switchboard Meters DC Battery Voltage Meters SBS’s Battery Monitor is a breakthrough in ground fault detection. This full Battery Voltage/Ground Meter/ Alarm Relay automatically indicates the instant a ground occurs. The optional hand-held ground fault locator finds the exact location of that ground, no matter where it is in the line. This highly accurate DC voltage meter relay provides voltage readings of battery, + or -BUS to ground, and ground fault voltages for protection of the essential BUS. The ground fault relays indicate the ground anywhere in the system, whether on the “ + “ or the “-” side. Over/Under Voltage relays are provided. Fail safe operation of the under voltage relay operates correctly down to zero volts. Time delay, which can be set from 5 to 60 seconds, is provided to avoid nuisance alarms. 50-469-BB Fault Indicator Specifications Ħ Operation - Hand-activated on-off button/switch Ħ Features - Automatic selection of grounded line. Does not interfere with sensitive electronic equipment, radio, etc. Ħ Receiver - Does not contact circuitry; LED and sound indicators Ħ Sensitivity - Up to 100Ù resistance Time Delay Can be set from 5 to 60 seconds Reset Panel push button or remote contact closure will reset an alarm provided the cause is removed Contact Rating 2A at 120 VAC or 28 VDC Limit Setting Limits and time delay are set by removing the front bezel (4 screws). This can safely be done with power on. Optional Fault Indicator (-BB) Information Operation: Produces current pulses between the transmitter and the ground fault. A pulse receiver can trace the line with these pulses to the ground. Circuit breaker in the line can be identified and open to clean the ground from the system. Features: Ħ On/off switch on front panel Ħ Automatic selection of grounded line Ħ Does not interfere with sensitive electronic equipment, radio, etc. Optional Hand Held Receiver: Part No. 200A Ħ Does not contact circuitry Ħ LED and sound indications Ordering Information Part No. Description 25-469 125Vdc battery voltage meter 25-471 48Vdc battery voltage meter 25-472 250Vdc battery voltage meter 200A Handheld receiver, suffix ‘-BB’ is required Accessory Ordering Information Suffix Description -BB Optional fault indicator added to voltage meter -J3.0 Digital RS323/485 with DNP3.0 or Modbus -1420 4 to 20 mADC, 1% accuracy -101 0 to 1 mADC, 0.1 accuracy Ordering Information Part No. Description 50-469-BB 125Vdc portable battery monitor Additional Voltages 50-471-BB 48Vdc portable battery monitor 50-472-BB 250Vdc portable battery monitor Accessory Ordering Information Suffix Description -J3.0 Digital Rs232/485 with DNP3.0 or Modbus -1420 4 to 20 mADC, 1% accuracy -101 0 to 1 mADC, 0.1 accuracy

pageCatalog pdf di En 2012-06-22-01