| | | Axiom | | |
| | | |
| | | Sensing & Communication Module | | |
| | | |
| | | Open and Closed Settings Switches correspond to a particular valve position and are set using the push button panel on the module's sealed membrane pad. Simply operate the actuator to the open position (using standard internal manual override) and push the "Set Open" button. Operate the actuator to the closed position and push the "Set Closed" button. Position settings remain locked in when power is removed and reapplied. (See pages 28 to 37 for more information.) | | DeviceNet VCT (92) Configuration (2) Discrete Inputs (Open & Closed) (1) 4-20 mA Auxiliary Input (2) Discrete Outputs (Drive Solenoids)5 Other Features Stores number of actuations Stores date of last service Predetermined output fail state Foundation Fieldbus VCT, Bus Powered (93) | | |
| | | |
| | | Configuration | | |
| | | (2) Discrete Inputs (Open & Closed) (2) Discrete Outputs (Drive Piezo)3 16 mA quiescent 9 to 32 VDC Stores number of actuations Stores date of last service Predetermined output fail state VCT, Bus Powered (94) (2) Discrete Inputs (Open & Closed) (2) Externally Powered Discrete Outputs (Drive Solenoids)5 16 mA quiescent 9 to 32 VDC 24 VDC Solenoid dependent Stores number of actuations Stores date of last service Predetermined output fail state | | |
| | | |
| | | Current Input Voltage Range Other Features | | |
| | | |
| | | |
| | | DeviceNet. | | |
| | | |
| | | Foundation Fieldbus Configuration | | |
| | | SST Switching Sensors (33) | | |
| | | |
| | | |
| | | Configuration | | |
| | | 2.0 Amps 0.25 Amps 2.0 mA 0.5 mA 20 to 125VDC/125VAC 7.0 Volts @ 100 mA Protected from Direct Application of up to 125VDC/VAC | | |
| | | |
| | | Signal Current Input Signal Voltage Range External Voltage Input External Current Input Other Features | | |
| | | Output Maximum Current Inrush Continuous Min. On Current Max. Leakage Current Voltage Range Max. Voltage Drop Short Circuit | | |
| | | |
| | | |
| | | Modbus VCT (95) Configuration | | |
| | | (2) Discrete Inputs (Open & Closed) (1) 4-20 mA Auxiliary Input (2) Discrete Outputs (Drive Solenoids)5 24 VDC 32 Predetermined output fail state | | |
| | | |
| | | |
| | | |
| | | Namur Sensors (44) | | |
| | | |
| | | Configuration Output Current Ratings Voltage Range | | |
| | | (2) Namur Outputs (1) or (2) Solenoid Power Input(s)2 Conforms to DIN 19234 Target On I < 1.0 mA Target Off I > 2.1 mA 7 to 24 VDC | | |
| | | External Voltage Devices per Network Other Features | | |
| | | |
| | | |
| | | 1. Specify Solenoid Option "_ H" 2. Specify IS Solenoid Option "_ E" | | 3. Specify Piezo Option "_ A" 4. Specify Solenoid Option "_ D" 5. Specify Solenoid Option "_ B" | | |
| | | |
| | | |
| | | |
| | | |
| | | AS-Interface VCT (96) | | |
| | | |
| | | Configuration | | |
| | | (2) Discrete Inputs (Open & Closed) (2) Auxiliary Discrete Inputs (2) Discrete Outputs (Drive Solenoids)45 2.1 26.5 to 31 VDC 31 | | |
| | | |
| | | The Axiom utilizes a magnetic resistive (Mag Res) sensor system that monitors exact valve position. The Mag Res sensor system is also tolerant of lateral and vertical shaft movement which may be experienced in high cycle worn industrial actuators without affecting rotational measurement. No cams, shafts and other mechanical apparatus are required that are prone to wear and binding. | | |
| | | AS-I Version Input Voltage Devices per Network | | |
| | | |
| | | |
| | | AS-Interface VCT (97) with Extended Addressing Configuration (2) Discrete Inputs (Open & Closed) (2) Auxiliary Discrete Inputs (1) Discrete Output (Drive Solenoid)4 AS-I Version 2.1 Input Voltage 26.5 to 31 VDC Devices per Network 62 | | |
| | | |
| | | |