Prism
Pneumatic control & Other Specifications
Solenoid Valve © = CZ]
A poppet style valve with exceptional tolerance to dirty air, the solenoid valve may be used for most conventional AC or DC applications. The DC (low power) version may be used on AS-lnterface, Modbus, DeviceNet bus powered applications and on Foundation Fieldbus (94) externally powered applications.
The three way, two position spring return pneumatic
valve is designed to operate single acting industrial actuators. Working mechanisms on the valve are completely isolat­ed from the environment enabling pneumatic control to be located in the field at the actuator with no threat of contamination. A standard rebreather enables exhaust
air from the pressurized actuator cylinder to be channeled into the spring side actuator chamber preventing the ingestion of contaminated air from the outside environment. Select a solenoid valve for conventional or device bus applications or a piezo valve for Foundation Fieldbus bus powered applications.
Filtration Requirements Operating Temperature DC Power Requirements AC Inrush Current AC Holding Current
AC Coil
40 Micron
-18°C to 50°C (0°F to 120°F) 1.8 Watts@24VDC (0.075mA) 0.09 Amps @120VAC 0.06 Amps @120VAC Warranted Against Burn Out
Piezo Valve ® = [p
The Piezo valve is ideally suited for use with the Foundation Fieldbus (FF) bus powered output module (93). Each module output provides up to 2mA @ 6.5 VDC which is sufficient to drive the piezo valve. Specifically designed for ON/OFF discrete applications, the piezo valve may remain ener­gized for extended periods of time with no memory effect.
Piezo Valve Specifications
Filtration Requirements 30 Micron Operating Temperature -10°C to 60°C (14°F to 140°F) DC Power Requirements 2mA @6.5VDC Hazardous Ratings EEx ia IIC T6
General Pneumatic (Solenoid & Piezo)
Configuration Porting
Rebreather Port Flow Ratings Rebreather
Specifications
3-Way, 2-Position, Spring Return 1/8" NPT all pressurized ports 4-40 size
Cv- 0.1 (Kv- 1.4)
Standard on all models; Diverts
air from Exhausting Cylinder into
Actuator Spring Side, Excess air
exhausted to atmosphere
1 Million Cycles
40psi to 120psi (2.6 to 8 bar)
Operating Life Operating Pressure
24 StoneL Corporation Phone: (218) 739-5774 • Toll-free: (800) 843-7866 • Website: www.stonel.com
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
pdf-page pdf di En 2008-10-41-07