| | R E G U L A T I N G V A L V E S | | | | | | |
| | | |
| | PRESSURE REGULATING VALVE PILOT OPERATED, SPOOL TYPE WITH RELIEVING FEATURE. ■ Maximum pressure setting up to 350 bar 5000 psi. ■ Low pressure rise/flow characteristic. ■ Spool valve for good stability. ■ Partial reverse flow capability. ■ Hardened working parts for maximum durability. ■ Adjustable, preset and tamperproof versions available. ■ Preset version is tamperproof and compact. operation The adjustable spring-loaded ball in the pilot section is shifted at valve setting by the regulated outlet pressure sensed through an orifice in the main spool from port [3]. The resulting pilot flow creates a pressure drop across the spring-loaded main spool that then meters the supply flow from port [2], maintaining the regulated pressure on port [3]. An increase in the regulated pressure causes the spool to lift further and acts as a service line relief valve, closing the supply port [2] and then relieving to port [1]. Ports [2] and [3] remain normally open when port [3] pressure is below the valve setting. Back pressure on port [1] adds to the valve setting. | | |
| | | |
| | | | | | |
| | | |
| | | |
| | | | Measured at 30 cSt 140 SSU (For cartridge only) 400_RELIEVING & REGULATING PERFORMANCE | |
| | | |
| | | | | | |
| | | |
| | | | | |
| | | |
| | | 10 - 210 bar 145 - 3000 psi | 10 - 350 bar 145 - 5000 psi | | | | |
| | | |
| | | | | |
| | SENSITIVITY: PRESSURE/TURN | | | |
| | | |
| | | MINERAL OIL OR SYNTHETIC FLUID WITH LUBRICANT PROPERTIES | BASIC VALVE PRESSURE DROP | |
| | | |
| | | |
| | | | 120 80 40 0 40 80 120 31.7 21.1 10.6 10.6 21.1 31.7 Flow l/min USgpm | |
| | | |
| | SEAL MATERIAL / TEMPERATURE * | NITRILE (Std.) -30°C to +100°C BUNA-N -20°F to +210°F | | |
| | | -20°C to +150°C -4°F to +330°F | |
| | | |
| | | 25 MICRONS (Nom.) OR BETTER | ■ Drain line should be piped directly to tank. Any back pressure in the drain line will be additive to the regulated pressure. | |
| | | | |
| | | | |
| | | |
| | * IMPORTANT: See pages 582-583 for additional notes on operating conditions. Specifications may change without notice | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | |