Manually operated , Poppet, 2 position, 2 way , Normally closed GM0201 - Sterling Hydraulics - #1 |
|
You may also be interested in
Flow control valve, Air operated valve, Valve, Check valve, Control valve
Text version of the page
MANUALDIRECTIO NALGM0201UP TO45L/MIN12 •USGPM AND210BAR3000PSIPOPPET TYPE2 Position 2 WayNormally ClosedTwo way on-off poppet valve with exceptional operatingcharacteristics. One piece cartridge housing ensures internal concentricity. Cavity common with solenoid operated valves.1OPERA TION Pulling knob, lifts pilot away from poppet allowing free flow fromport 1 to port 2. Reverse flow is restricted when applying pressure to port 2.2SPECIFICATIONS TYPICAL PERFORMANCEBASIC MODELNUMBERSYMBOLMAXIMUM RATEDFLOW SEAL MATERIAL/TEMPERATURE Measured at 30cSt 140 SSU (For cartridge only)GM02 0121 PRESSURE DROP vs.FLOW (CARTRIDGE ONLY) 21 300 17.5 250 45 l/minpsi 14.0 12 USgpm 200 MAX INPUTPRESSURE AT PORT 1IDEAL VISCOSITY 210 bar 10.5 3000 psi 150 MAX INTERNALLEAKAGE AT 210 bar 7.0 100 3000 psi 0.33 ml/min Pressure Drop bar at 38 cSt 180 SSU 5 drops/min. 50 FLUID MINERAL OIL OR SYNTHETIC FLUIDWITH LUBRICANT PROPERTIES15-50 cSt NITRILE (Std.)-30°Cto+100°C 80-230 SSU 003.5 7.6 15.2 22.7 30.2 38.0 45.4 2 4 6 8 10 12 BUNA-N-20°Fto+210°F Flow l/min USgpm FILTRATION VITON-20°Cto+150°C -4°Fto+330°F CART. WEIGHT 25 MICRONS (Nom.) OR BETTER 0.10 kg 0.23 lb IMPORTANT: See pages 582-583 for additional notes on operating conditions.Specifications may change without notice. 242 |
|