PART-NUMBER
RMP 40.8900
Output PART-NUMBERS PART-NUMBER
G 3/8 HVB 09.5102/IA/JV
HVB 09.2000/IA/JV
G 1/2 HVB 09.5103/IA/JV
NPT 1/2 HVB 09.5203/IA/JV
UN 9/16 - 18 * HVB 09.5314/IA/JV
UN 3/4 - 16 * HVB 09.5319/IA/JV
Complete plate conversion kit from RMP 48 to RMP 49
please contact us.
Parking plate
240
112
We reserve the right to modify product specifications without prior notice.
Technical specifications
ƒÞ Shut-off
• double
ƒÞ Leaktight seal
• Fluorocarbon (FPM) as standard.
ƒÞ Conditions of use of plates
• Min. / max. working temperature:
- 10 to + 200 °C.
• Max. working pressure:
3 x 180 bar couplings (supply circuit)
and 3 x 10 bar couplings (output circuit).
ƒÞ Flow rate / pressure drop charts
Flow in l / min
Pressure drop in bars
0,1
0,2
0,3
0,4
0,5
0,7
1
2
3
4
5
10
1 2 3 4 5 10 20 30 50 100 200
V = 30 m/s
V = 10 m/s
V = 5 m/s
Cv = 2,98
• Test conditions:
- Hydraulic oil INVAROL FJ 13 (H515) at 40°C
- Density at 40°C: 833 kg/m3
- Kinematic viscosity at 40°C: 13.4 cSt
- Direction of flow: socket plug
Plate component
Press equipment Mould equipment
7
* according to SAE J1926-1