| | | Active Vibration Isolation System 0 | | |
| | | ITS-200 | | |
| | | |
| | | This moderately priced dynamic vibration isolation system achieves in a very small volume better isolation than is possible with the biggest and most expensive passive systems. Inertial feedback is used via electromagnetic transducers to provide not only isolation from building vibrations, but also isolation from vibration sources placed on the system itself. This means, for example, that a delicate microscope isolated by the system will remain at rest despite forces being applied via the operator's hands. The inherent stiffness of the system, typically 25 times greater than that of a 1 Hz resonance passive isolator, imparts excellent directional and positional stability. The characteristics of an active isolation system are typified by the virtual lack of any low frequency resonance, a resonance which plagues all passive isolation systems. The 1TS-200-M is a complete active isolation system measuring 210x210x125 mm per single unit. The system isolates against all six possible translational and rotational vibration modes and has been designed to offer excellent isolation even at frequencies as low as 2-3Hz, where many buildings show large horizontal amplitudes due to oscillation about the vertical axis. | | |
| | | |
| | | £o CO | | |
| | | |
| | | ™ n w n ° C/l re g re o 2 | | |
| | | |
| | | IO | | |
| | | SO | | |
| | | |
| | | |
| | | O № 3 — | | |
| | | |
| | | O.I | | |
| | | |
| | | S o | | |
| | | |
| | | O.OI | | |
| | | |
| | | I IO Frequency (Hz) | | |
| | | O.I | | | 1OO | | |
| | | 8C | | |
| | | | |
| | | |
| | | |
| | | |
| | | 2 | | |
| | | |
| | | SPECIFICATIONS | | |
| | | |
| | | Isolation Transmissibility Correction forces System noise Minimum load Maximum load Static compliance Electrical Safety class Power consumption Input voltage Fuses | | Dynamic I Hz to lkHZ, purely passive beyond 1kHz See attached curve. Above 10 Hz transmissibility <0.01 (-40dB) Maximum ±4N in any direction Less than 20 n/GVHz from 0.1-200 Hz in any direction —100 kg (four legs) 800 kg (four legs) approx. 120 m/N vertical approx. 30-400 m/N horizontal | | |
| | | o C8o8SoC CD ft" fl) | | |
| | | |
| | | 00 l/l e ti re 2 | | |
| | | |
| | | |
| | | Typically IO W, maximum 50 W (70 VA) 115-230 V AC±10%, 50-60 Hz 2x1.6A/250V slow, located in the power socket on the rear side of the unit | | |
| | | in | | | 88 | | |
| | | |
| | | |
| | | |
| | | |
| | | Normal Environmental Conditions Protection class Temperature range | | |
| | | IP 20 5°C - 40°C | | |
| | | 1 o | | |
| | | |
| | | |
| | | |
| | | 10 - 90% (5 - 30°C)/10 - 60% (30 - 40°C) Indoor Up to 2000 m (6.500 ft) | | |
| | | elati e Application Altitude | | midity | | |
| | | = 3s 8 reg. 3 q // re re 8 = 32 | | |
| | | |
| | | |
| | | |
| | | |
| | | | | |
| | | |
| | | | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |