video corpo

CIRCULATING PUMP
36Pages

{{requestButtons}}

Catalog excerpts

CIRCULATING PUMP - 1

CIRCULATING PUMP WATER PUMPS

Open the catalog to page 1
CIRCULATING PUMP - 2

WATER PUMPS PUMPING TECHNOLOGY Until recently, central heating installations in private house building used mainly gravity water circulation. In such a cycle, the water circulates in the installation thanks to the density difference caused by temperature difference between the supply (the outlet of heated water from the boiler) and the return (the inlet of cool water from the radiators back into the boiler). The faults of such a system include significant inertia, non-uniform distribution of heat and big diameter pipelines. Presence of a pump in a central heating installation allows to...

Open the catalog to page 2
CIRCULATING PUMP - 3

PUMPING TECHNOLOGY WATER PUMPS Selection of electronically controlled pumps Functioning of electronically controlled pumps has been adjusted to annual heating energy consumption standards. The average annual consumption is showed in figure 2, illustrating seasonal overload. The proper selection of regulated pumps is shown in figures 3, 4 and 5. (Comparison of pump's characteristics determined by the design with actual technical characteristics of a particular pump). Regulation 'of eortslant pressure P Regulation fw proportional pressure p The pump is over motored While using regulated pumps...

Open the catalog to page 3
CIRCULATING PUMP - 4

WATER PUMPS PUMPING TECHNOLOGY Practical advice Electrical connection Connect the electric cables and earthing with a slight sag to the terminal strip, and plug in according to the marking. External electric protection is not required. The pump motor can be placed freely at 90° to the pump body, nevertheless it is important that the cable lead is not turned upwards and the terminal box is not located below the motor (see figures 2, A1, A2, A3, A4). The terminal box connection and the contacts between the box and the motor winding must be protected against humidity. It is forbidden to mount...

Open the catalog to page 4
CIRCULATING PUMP - 5

PUMPING TECHNOLOGY WATER PUMPS

Open the catalog to page 5
CIRCULATING PUMP - 6

CIRCULATING PUMP INDEX Pumping Technology SCRA SCR SCRE PLUS Technical Characteristics. The technical data and characteristics stated in this General Catalogue are not binding. SPERONI spa reserves the right to make modifications without notice. Therefore weights, dimensions, performances and any other stated issues are indicative only and not binding. Anyway for any technical details you must require an up-to-date product technical card. Competent Court. In case of any dispute the competent Court will be one of Reggio Emilia even if the payment is by bill of exchange.

Open the catalog to page 6
CIRCULATING PUMP - 7

BOOSTER CIRCULATING PUMPS 20/90-160 Applications Circulating pump designed for pressure boosting of water in domestic properties. The pump provides additional pressure to showers,taps. The pumps incorporates a flow switch starts or stops the pump when a tap is turned on or off Motor - Input power P1 120 W - Nominal power P2 40 W - Capacitor 3 µF - Current input 0,48 A - Single-phase 230 V - 50 Hz. - Duty continuous S1 - Insulation class H - Protection IP 42 - 2 pole induction motor Operating condition - Liquid temperature max 70 ¡C. - Ambient temperature up to 40 ¡C. Pump - Pressure lead...

Open the catalog to page 7
CIRCULATING PUMP - 8

WATER PUMPS Central heating circulation pumps Technical data single-phase motor with a wet rotor three rotational speeds connection: external thread GZ 1", 1 1/4", The pump has been created to pump warm water in central heating systems, however it can be used to pump liquid media in industrial and commercial usage. The pump may also be a part of a solar heating The articles are manufactured from the highest quality cast iron and chrome-nickel steel, which guarantees that the products are of high quality. The product has a ceramic bearing ring and a rotor disk made of technical polymer....

Open the catalog to page 8
CIRCULATING PUMP - 9

Dimension illustration

Open the catalog to page 9
CIRCULATING PUMP - 10

WATER PUMPS CIRCULATING FOR HEATING AND CONDITIONING ELECTRONIC Energy-saving Speroni SCRE 40 - SCRE 60 electronic circulation pumps for central heating Along with the series Delta plus we have achieved a circulation pump which is classified in energy efficiency class "A". Using a Speroni pump instead of a conventional circulation pump helps to reduce energy consumption up to80%, while keeping the hydraulic power at a comparable level. The "One touch" option allows you to choose from six different performance curves.

Open the catalog to page 10
CIRCULATING PUMP - 11

Performance curve models

Open the catalog to page 11
CIRCULATING PUMP - 12

WATER PUMPS ELECTRONIC CIRCULATING PUMPS FOR CENTRAL HEATING Energy-saving Speroni SCRE PLUS 40 - SCRE PLUS 60 electronic circulation pumps for central heating Along with the series Delta HE we have achieved a circulation pump which is classified in energy efficiency class "A". Using a Speroni pump instead of a conventional circulation pump helps to reduce energy consumption up to 80%, while keeping the hydraulic power at a comparable level. The "One touch" option allows you to choose from seven different performance Technical data electronically regulated power: operating voltage: motor...

Open the catalog to page 12
CIRCULATING PUMP - 13

SCRE PLUS- The display is lit when pump is plugged in. The LED display shows the current power Faults are shown on the display as "E1", "E2" or "E3" errors. When the night setback function is activated and the pump is switching to this mode, then the "-C" symbol appears Curve selection button By pressing the button pump settings change. Pressing the button seven times causes to select one by one all the options and then return to the first one. Display Description I_constant rotation speed I_ II_ constant rotation speed II II]_constant rotation speed III_ PD1 low curve of proportional...

Open the catalog to page 13
CIRCULATING PUMP - 14

WATER PUMPS ELECTRONIC CIRCULATING PUMPS FOR CENTRAL HEATING SCRE PLUS Pump settings Regulation of proportional pressure When operating the pump adjusts to the settings of proportional pressure. Whereas differential pressure is controlled by the pump, depending on the current of the flow. Lines (characteristics) of proportional pressure are denoted with PD1 to PD4 symbols on corresponding Constant rotation speed control Lines (characteristics) of constant speed rotation are denoted with I to III symbols on the Q/H graph. This type of control allows the pump to maintain constant rotation...

Open the catalog to page 14

All Speroni catalogs and technical brochures

  1. CS 80

    8 Pages

  2. CMA 80

    1 Pages

  3. SXT 636

    1 Pages

  4. PS 2CM

    1 Pages

  5. PS VS

    6 Pages

  6. RSM 40/80

    2 Pages

  7. CX 50

    8 Pages

  8. CS 65

    2 Pages

  9. REM

    2 Pages

  10. AIRMEC ENGINE

    102 Pages

  11. AIRMEC

    102 Pages

  12. EUROMATIC

    52 Pages

  13. RVM-RV 3-4-5

    1 Pages

  14. WATER PUMPS

    164 Pages