> THE DETAILS MAKE THE DIFFERENCE
INTEGRATED THERMOSTAT-CONTROLLED HEATING
Condensation and morning dew, humidity in the interior of the column caused by high air température, and snow collecting on the caps are all important factors to take into consideration for effective exterior detection. COLIRIS II integrates a thermostat-controlled heater (1) on each cell precluding the formation of ice, dew and condensation. It also makes it possible to melt snow on the caps or to dry out the interior of the column.
SORHEA
PERIMETER ■ SURVEILLANCËH
OF SENSITIVE SITES
MANUAL ALIGNMENT WITHOUT SPECIAL TOOLS
Each cell can be aligned manually without having to use special tools (screw
driver, pliers, etc.). The focusing knobs (2) permit rapid and precise alignment
of each cell.
COLIRI
INTEGRATED OPTIONAL 230VAC OR 110VAC POWER SUPPLY
COLIRIS II is available with an optional 230Vac or 110VAC power supply integrated directly in the column. Beyond the esthetic aspect (absence of an external supplementary housing), this
option also simplifies wiring and allows direct control of heating. It also allows resolution of line-drop problems linked to long cable lengths on large sites. The 230Vac or 110VAC power supply can power single or double direction columns.
> NEW DIS. CELLS INNOVATION FOR GREATER RELIABILI
ANTIGLARE FEATURE
Thanks to this feature, COLIRIS II is completely immune to glare directly on the receiver from possible powerful light sources, such as the setting sun or headlights of cars.
> TECHNICAL SPECIFICATIONS
IR barrier range (*)
50m (155ft) - 100m (330ft) - 200m (660ft)
Power supply voltage
10,5-14 ac/dc
Power supply voltage for control electronics separate from that for heater
Consumption without heater
140mA each column
680mA each column
Heating consumption
Height
1m - 1,50m - 1,90m
Operating temperature
(with thermostat controlled heating) -25°C (-13°f) to +55°C (131°f)
CD O O C\l
ai o
180° in horizontal planeE* j and + or - 10° in vertical plane
Cell orientation
response time
Adjustment of response time for detection with potentiometer (50 ms to 800ms)
o >
An optical sighting lens in each cell Integrated alignment assistance
Alignment
CN CM O LU O Z
Output
NC tamper output
1 timed disqualification output per NC switch and control indicator light. 1 intrusion output per NC switch and control indicator light
Number of channels
4 channels of selectable infrared pulsating frequencies
Heating
Thermostat-controlled heating on all columns
o o
CN
(D _Q
E
.£ Q_
CD CO
@
O
CO CN O O
Wiring
Pre-wired columns
Integrated 230V or 110VAC power supply
Options
(*) Range relative to visibility, not to exceed 100 m in regions where fog may be dense
In order to continuously ensure the high stan­dard of quality and performance of our products, we reserve the right to modify the present technical data without notification.
1, rue du Dauphiné - F - 69120 VAULX-EN-VELIN Phone. +33(0)4 78 03 06 10 - Fax +33(0)4 78 68 24 61 Mail : export@sorhea.fr - Web : www.sorhea.com

pageCatalog pdf di En 2012-05-22-31