TECHNICAL INFORMATION

TypeCapacity per set of 4
1 2 Nl/min SCFMModule typeAir pressure
3 5 kg lbsAir consumption kPa psiAmmBmmCmmDinE inControl unit type
MLS 4083000 6600750 25ML 8300 4320431/51
4
101/21MRB 4-15MLS 4127000 154001120 39ML 12300 4330431/51
4
151/21MRB 4-15MLS 41510000 220002200 77ML 15300 4338031/51
4
201/21MRB 4-15MLS 418S11000 242002600 92ML 18S300 4345758203/41MRB 4-20 MLS 421S14000 310003000 106ML 21S210 3053458253/41MRB 4-20 MLS 427S24000 530003400 120ML 27S210 3068465353/41 1/2MRB 4-20 MLS 436S44000 970004000 141ML 36S210 3091471503/41 1/2MRB 4-20MLS 418H20000 440004600 162ML 18H410 5945758203/41MRB 4-20MLS 421H28000 620005200 184ML 21H410 5953458253/41 1/2MRB 4-20 MLS 427H48000 1060006000 212ML 27H430 6268465353/41 1/2MRB 4-20 MLS 436H80000 1760007000 247ML 36H400 58914715011 1/2MRB 4-25 MLS 442H120000 2650007500 262ML 42H400 581070716512MRB 4-25MLS 448H160000 3530008000 282ML 48H450 651220717512MRB 4-25
A Air bearing moduleC = Nominal lifting heightD = Internal diameterSupply hoseL= 4 mSupply hoseL= 6 mControl unitShut-off valveQuick releasecouplingE = Internal diameterCompressed air supply 600 kPa = 6 bar (90 psi)

The Modular Air Bearing System includes:

B C

• 4 air bearing modules• 4 supply hoses with quick release couplings • Control unit equipped with pressure regulator and gauge for each module and supply pressure gauge • 30 m supply hose including shut-o valve• Operating instructions

A D E

Optional:

• Remote control unit • Control unit for six-module system• Alternative hose lengths • Outlets for air jacks

Ab Solving Oy PO Box 98 FI-68601 Jakobstad FinlandTel. +358 6 781 7500 Fax +358 6 781 7510 info@solving. www.solving. 1) The modules must be placed under the load so that each one sees no more than one quarter of the full system capacity. 2) These gures refer to good oor conditions, e.g. power-trowelled and sealed concrete surfaces.3) Air pressure in air bearing element at max load (100 kPa = 1 bar).4) Cast aluminium/Extruded aluminium construction. 5) Supply hose ID and shut-o valve thread size.