You may also be interested in
Text version of the page
| | | | | | | | | | | |
| | | |
| | | SOLID Applied Technologies Ltd. MonoScan/MicroScan - 5P Installation tips Power-Pipes-Positioning-Programming-Physics | | |
| | | |
| | | | | | | | | | | Power | | | | | | Voltage | MUST BE | 12 Volts or more on the terminals. | | | | A battery | MUST BE | rated higher than 12 Volts due to normal voltage drop. | | | | Rechargeable supply | MUST BE | non operational when switched to recharge. | | | | PLC connections | MUST BE | as specified in the user manual, preferably grounded. | | | | Pipes | | | | | | Extension pipes | MUST BE | of internal diameter 3.5" min and length of 25 cm max. | | | | Extension pipes | MUST BE | preferably plastic and non-perturbing into the tank. | | | | Positioning | | | | | | Distance to tank walls | MUST BE | at least 50 cm. Add 10 cm spacing for each 1m in range. | | | | sensor | MUST BE | exactly perpendicular to the surface of target. | | | | Programming | | | | | | Tank height, level/distance | MUST BE | configured correctly. | | | | SBD | MUST BE | configured in flange / extension pipe based installations. | | | | Interfering signals | MUST BE | defined when tank is empty. | | | | Physics | | | | | | Acoustic noise and vibrations | MUST BE | minimized, reducing interference with echoes. | | | | Physical obstacles and dust | MUST BE | absent along the echo path. | | | | Electrical interference | MUST BE | shielded away from power and sensor cables. | | | | | | | | | | |
| | | |
| | | Solid Applied Technologies Ltd Solid House, 48 Montefiore St., Tel Aviv 65201, Israel Tel(972-3)7101440 | | www.solidAT.com info@solidgroup.com Fax (972-3)7101405 | | |
| | | |
| | | | | | | | | | | |