Introducing MicroScan C HAPTER 1 3
MicroScan User Manual - 15188 MicroScan SpecificationsAccuracy 0.25%* of measuring range Resolution 1 mm (0.04") Beam angle 5 ° @ 3db point Ambient temp’ compensation Automatic* 0.25% or 1.25cm whichever is greater. Measuring RangesMicroScan L for liquids 0.25 m — 5 m 0.8 ft — 16.4 ft MicroScan S for solids 0.25 m — 3.5 m 0.8 ft — 11.5 ftMechanical SpecificationsEnclosure IP 65, mono-block construction. Plastic enclosure: ABS+UV Wetted parts Sensor body: PolyProp. PVDF, optional. Stainless Steel for Liquid model; Coated Aluminum for Solid/Liquid model. Operating temperature -40 C to + 70 C (-40 F to +158 F) Mounting 2" BSP or 2" NPT |