Reader, Inputs and Outputs
Reader Ports.................16
Reader Support...............RM readers or RM reader modules, or
Wiegand output readers
Reader Technologies Supported
• Multi-Technology • Smart Card • Magnetic Stripe
• Proximity • Wiegand
Maximum Distance to Door......RM: 1,219 m (4,000 ft)
Wiegand: 150 m (500 ft) RM Bus Communications.......RS-485 half duplex, two wire, plus
optional two wires for device power
Supervised Inputs.............32, double-resistor
Input Expansion...............Up to 128 additional inputs using I8
input modules on RM bus
Outputs.....................16 dry contact relay outputs
Output Rating................30VAC/DC, 2.5A inductive, 5.0A
non-inductive
Output Expansion.............Up to 128 additional Form C Relay
outputs using R8 output modules on RM bus
Tamper Switches..............Two, front and rear cover
Model Numbers
STAR008-2URM..............iSTAR Pro 2U Rack Mount, supports
eight RM readers (16 inputs and eight outputs included)
STAR016-2URM...............iSTAR Pro 2U Rack Mount, supports
16 RM readers (32 inputs and 16 outputs included)
STAR008-2UW...............iSTAR Pro 2U Rack Mount, supports
eight Wiegand readers (16 inputs and eight outputs included)
STAR016-2UW................iSTAR Pro 2U Rack Mount, supports
16 Wiegand readers (32 inputs and 16 outputs included)
Physical
Dimensions (H x W x D).........8.9x 48.3 x 58.4 cm
(3.5x19.0x23.0 in)
Rack Space Requirements......2U (standard rack units)
Environmental................0°to 50°C (32° to 122°F)
5 to 95% relative humidity
non-condensing
Weight......................15kg(33 lbs)
High Temperature Alarm........60° +/- 6°C (140° +/- 10°F)
Electrical
Power Requirements...........90/264 VAC, 50/60 Hz
Input Protection...............4A/250Vfuse
Power (Max)..................75W
Heat Dissipation (Typical)........320 BTU/h
Memory and RTC Backup.......Onboard, rechargeable NimH batteries
provide minimum 12 hrs retention of
RAM and RTC
Network Communications.......10/Base-T Ethernet onboard
Second LAN Port..............Using optional 10/100 PCMCIA
network card
Indicators and Switches
LED for power, high temp LCD for diagnostics
System Memory
64 MB RAM standard; expandable to 128 MB
Regulatory
Tested and certified by ETL per ANSI/UL standard 294-2004
CE
FCC Part 15 Class B
RoHS
Power supply certified to CSA C22.2 No. 60950-1-03
Controller Capacity 64 MB
Controller Capacity 128 MB
Number of personnel records with one clearance, one card/ person, ten-digit cards
525,000
1,200,000
Number of personnel records with ten clearances, one card/ person, ten-digit cards
295,000
680,000
Number of personnel records with one clearance, five cards/ person, ten-digit cards
170,000
375,000
Number of personnel records with ten clearances, five cards/ person, 40-digit cards
110,000
250,000
Typical Rear Wiring per Door, RM Models
Typical Rear Wiring per Door, Wiegand Models
+12V
D+
D-
GND SHIELD
IN1 IN1 IN2
IN2
LOCK C
LOCK NO
WIEG+ GND DATA 0
DATA 1
RED
GREEN
IN1
IN1
IN2
IN2
LOCK C LOCK NO
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products Include all features. Availability varies by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies