Power protection solutions for IT Power protection solutions for IT catalogue - 37 / 44 Pages

ASYS

16 A, 19” Rack mounted
Automatic Transfer System

Front view

Application Rack
1
2
4
6

ASYS 003 A

1
2

RS232

ASYS
8
7
5
3

Preferred source indication
Preferred source selection
Input source status
Supplying source
General alarm
Buzzer acknowledge
RS232 communication port (MODBUS RTU)
Dry contacts communication port

AS
YS

1
2

ASY
S
RS

PO
SOWE
UR R
CE
PO
1
SOWE
UR R
CE
2

Technical data
ASYS
16A-120
120 V

120 V

16A-230
220/230/240 V (selectable)
± 12% (± 20% available on request)
50/60 Hz (auto sensing)
± 15%
16 A

UPS 1
UPS 2

Example of possible
architecture

1
2

RS2

32

PS

U
2

1

2 x IEC 320-C20
1 x IEC 320-C19

S

AS
YS

PS

AWG12X3C/20A
4 x NEMA 5-20R

SY

A

220/230/240 V (selectable)
± 12%
50/60 Hz
± 15%
16 A
6 ms (typical), ≤ 15 ms (maximum)

U

Model
INPUT
Rated voltage
Input voltage tolerance
Rated frequency
Frequency tolerance
Rated current
OUTPUT
Rated voltage
Input voltage tolerance
Rated frequency
Frequency tolerance
Rated current
Transfer time
CONNECTION
Input
Output
Communication
ENVIRONMENT
Operating ambient temperature
Relative humidity
Maximum altitude
Acoustic level at 1 m (ISO 3746)
Cooling
MECHANICAL SPECIFICATIONS
Dimensions W x D x H
Weight
Degree of protection
Colours
STANDARDS
Safety
EMC

ASYS 010 A GB

232

5 dry contacts, RS232

ASYS 009 A

1.
2.
3.
4.
5.
6.
7.
8.

0 to 40 °C
20% - 85% without condensation
≤ 1000 m without derating
< 25 dBA
Natural
430 x 315 x 44 mm (1U)
5 kg
IP30
Pantone 432C
IEC 62310-1
IEC 62310-2

Catalogue 2013

37

Power protection solutions for IT Power protection solutions for IT catalogue
  1. P. 1

  2. P. 32

    MASTERYS BCSingle-phase andthree-phase UPSfrom 15 to 40 kVAsolutions for your business critical applicationsThe solution for> Data centres> Telecommunications>...
  3. P. 33

    MASTERYS BCfrom 15 to 40 kVASingle-phase and three-phase UPSStandard electrical features• ual input mains.D• nternal manual bypass.I•...
  4. P. 34

    CPSS Emergency*Single-phase UPSfrom 3 to 40 kVAa centralized power supply for your emergency systemsThe solution for> Airports> Railways and bus...
  5. P. 35

    CPSS Emergencyfrom 3 to 40 kVASingle-phase UPSTechnical dataMODULYS4.53.22.6•-64.23.5•-1097.5••1513.511.3••230 V (1ph...
  6. P. 36

    ASYSAutomatic TransferSystem16 A, 19” Rack mounteda secure power supply close to your applicationYour protection for> Rack servers> IT applications>...
  7. P. 37

  8. P. 38

    RACK PDUPower ManagementSolutionmonitored and managed rack PDUPower Distribution UnitYour protection for> Data centre rack cabinet> Networking infrastructurePDU...
  9. P. 39

    RACK PDUmonitored and managed rack PDUPower Management SolutionZero-U PDUConnections1.2.3.4.5.6.7.PDU 002 A12456O N-OFF switch segment #1O N-OFF switch...
  10. P. 40

    LOCAL VIEWLOCAL VIEW is a monitoring andmanagement software for UPS systems viaUSB or serial RS232 allowing the system’sautomatic shutdown in the...
  11. P. 41

    NET VISIONLOGIC 026 AIP network management solutionprofessional LAN adapter for remote UPS monitoring and controlNET VISION LAN adapter allows a directconnection...
  12. P. 42

    Communication interfacesSoftwareManagement solutionsEMD (Environment Module Device)EMD is a device to be used in conjunctionwith some LAN interfaces and...
Text version

All SOCOMEC catalogues and technical brochures

  1. UL 1008 & UL 98

    20 Pages

    En