Group: SMC
Catalog excerpts
Membrane Air Dryer New RoHS Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point (–60 C) No vibration or heat discharge Purge air flow rate (L/min [ANR]) Energy saving Reduced in purge air flow by up to Existing model 140 New 120 21,060 Series IDG50A yen/year ! Reduction ratio 31% Purge air flow rate (rated conditions) 100 80 Model 60 40 0 IDG A Cost reduced by up to 180 160 39 (L/min [ANR]) Reduced purge 0.0 1.0 0.5 Inlet air pressure (MPa) Variations Purge air flow rate Purge ratio (L/min [ANR]) (%) Running cost (yen/year) 46,440 86 15 67,500 New IDG50A Existing model 125 20 [Calculation conditions] Air unit price: 3 yen/m3 Operating hours: 12 hours/day Annual operating days: 250 days/year Unit Type Single Unit Type Reduced purge IDG A Series IDG A Purge air flow reduction type A white body is introduced. Mist separator + + Micro mist separator Micro mist separator IDG Tube configuration low flow rate type When dry clean air and pressure control are required. Mist separator IDG1 When dry clean air is required. IDG + + + Regulator Single Unit Body size Standard dew point 1 3, 5 10, 20 30 50 60 75 100 −20 C/Nil −15 C/Type H −40 C/Type L New −60 C/Type S Series IDG A/IDG IDG A IDG CAT.ES30-7E
Open the catalog to page 1Membrane Air Dryer Space Total length is shortened. saving Max. 59 mm Size 30 50 60 75 269 308 348 418 315 392 472 542 IDG A Series Under SMC test condition Time to reach the rated dew point (minutes) 483 271 Reduced purge 100 A Existing model High Time to reach the rated dew point performance Shortened by 40 minutes Series New IDG Standard dew point: –40 C/L, –60 C/H Model New IDG100SA 60 60 90 40 minutes Reduced purge Existing model IDG A 100 Series 483 mm 542 mm Dew point indicator 59 mm IDG100LA, 100SA Existing model Dew point indicator visually confirms air drying. (Except IDG1)...
Open the catalog to page 2Series IDG A/IDG Dehumidification Principle The membrane air dryer uses hollow fibers composed of a macro molecular membrane through which moisture passes easily, but is difficult for air (oxygen and nitrogen) to pass through. When humid, compressed air is supplied to the inside of the hollow fibers, only moisture permeates the membrane and moves to the outside due to the pressure difference between the moisture inside and outside of the fibers. The compressed air becomes dry air and continues out of the dryer. Part of the dry air from the outlet side is passed through a very small orifice...
Open the catalog to page 3Series Variations Meets a wide variety of flow rates (10 to 1000 L/min [ANR]) and dew points (Atmospheric pressure dew point: –15 C to –60 C). Single Unit Type Standard dew point: –20 C Standard dew point: –15 C Standard dew point: –40 C Standard dew point: –60 C Series Outlet air flow rate L/min [ANR] Series Outlet air flow rate L/min [ANR] IDG1 25 IDG3H 50 IDG5H Series Outlet air flow rate L/min [ANR] 25 IDG5 Outlet air flow rate L/min [ANR] 10 IDG3 Series 50 Page 1 Page 2 IDG10 100 IDG10H 100 IDG20 200 IDG20H 200 IDG30A 300 IDG30HA 300 IDG30LA 75 IDG50A 500 IDG50HA 500 IDG50LA 110 IDG60...
Open the catalog to page 4Series IDG A/IDG Unit Type A mist separator, micro mist separator, or micro mist separator with pre-filter combined with a single unit Standard dew point: – 20 C Standard dew point: –15 C Standard dew point: – 40 C Standard dew point: – 60 C Series Outlet air flow rate L/min [ANR] Outlet air flow rate L/min [ANR] Series IDG3M3 25 IDG3HM3 50 IDG5HM3 Outlet air flow rate L/min [ANR] Series Outlet air flow rate L/min [ANR] 25 IDG5M3 Series 50 IDG10M3 100 IDG10HM3 100 IDG20M3 200 IDG20HM3 200 IDG30AM3 300 IDG30HAM3 300 IDG30LAM3 75 IDG50AM3 500 IDG50HAM3 500 IDG50LAM3 110 IDG60M2 600 IDG60HM2...
Open the catalog to page 5Membrane Air Dryer/Single Unit Type Series BIDGUA Standard dew point temperature and air flow rate Thread type Note) In the case of two or more options, indicate them alphabetically. Note) When symbol B is indicated, a bracket assembly with a part number shown in the table left below is included as an Port size Bracket Assembly (Accessory) Part No. * With cap bolts (2 pes.) and spring washers (2 pes.)
Open the catalog to page 6Membrane Air Dryer/Single Unit Type Standard dew point temperature and air flow rate* Thread type Note) When symbol B is indicated, a bracket assembly with a part number shown in the table left below is included as an accessory. • Port size Bracket Assembly (Accessory) Part No. Note) In the case of two or more options, indicate them alphabetically. * With cap bolts (2 pes.) and spring washers (2 pes.)
Open the catalog to page 7Series Reduced purge IDG A Series IDG A/IDG Standard Specifications/Single Unit Type (Standard dew point −20 C, −15 C) Standard dew point…−20 C IDG1 IDG3 Standard performance conditions Range of operating conditions Model Fluid Inlet air pressure (MPa) Inlet air temperature (°C) Note 1) Ambient temperature (°C) Note 1) Standard Outlet air atmospheric perfor- pressure dew point ( C) mance Inlet air flow rate (L/min [ANR]) Note 2) Outlet air flow rate (L/min [ANR]) Purge air flow rate (L/min [ANR]) Note 3) Inlet air pressure (MPa) Inlet air temperature ( C) Inlet air saturation temperature (...
Open the catalog to page 8Membrane Air Dryer/Single Unit Type Series Reduced purge IDG A Series IDG A/IDG Standard Specifications/Single Unit Type (Standard dew point −40 C, −60 C) Single Unit Type Standard dew point…−40 C/Type L V M Unit Type Standard performance conditions Range of operating conditions Model IDG30LA IDG50LA IDG60LA IDG75LA IDG100LA Compressed air Fluid 0.3 to 1.0 Inlet air pressure (MPa) −5 to 50 Inlet air temperature ( C) Note 1) −5 to 50 Ambient temperature ( C) Note 1) Standard Outlet air atmospheric perfor- pressure dew point ( C) −40 mance Note 2) 93 135 224 308 400 Inlet air flow rate (L/min...
Open the catalog to page 9Series &IDGHA/IDG Conditions: Inlet air temperature 25°C (saturated air), Ambient temperature 25 C, P1: Inlet air pressure, Tube for purge air discharge (Option: P): None Note: Correcting outlet air flow rate is required depending on inlet air temperature. Refer to page 31 or after for details. For model with fitting for purge air discharge (Option: P), the outlet air atmospheric pressure dew point may become higher depending on the tube length for purge air PsrformanC© Chart discharge. For other models, if the tube length is 5 m or less, a rise of the outlet air at the atmospheric pressure...
Open the catalog to page 10All SMC PNEUMATIC catalogs and technical brochures
-
SYJ300/500/700 Series
62 Pages
-
Vacuum Unit ZK2 Series
60 Pages
-
Air Cylinder CJ2 Series
117 Pages
-
AS-FS Series
36 Pages
-
IDF series
12 Pages
-
MHL2 Series
24 Pages
-
JCM Serie
18 Pages
-
EX245 Series
12 Pages
-
Pin Cylinder CJP2/CDJP2/CJP
19 Pages
-
5 Port Solenoid Valve VQC
63 Pages
-
5 Port Solenoid Valve VQ
79 Pages
-
SY
268 Pages
-
5-p0979-0980-hep500
2 Pages
-
5-p0977-0978-aep100
2 Pages
-
5-p0966-0971-lmu
5 Pages
-
5-p0960-0966-alb900
6 Pages
-
5-p0956-0960-ald600
5 Pages
-
5-p0948-0950-al800
3 Pages
-
es70-44c-vx2
52 Pages
-
es50-37-kq2
124 Pages
-
ex-pcw
23 Pages
-
1-p2124-2152-ex510
29 Pages
-
1-p2111-2122-ex500
12 Pages
-
1-p2063-2073-ex260
11 Pages
-
4-p0147-0178-msu-mds
32 Pages
-
es20-230b-crb2
59 Pages
-
1-p1869-1878-vp3145
10 Pages
-
VP300/500/700 series
42 Pages
-
1-p1789-1829-vqz100
41 Pages
-
1-p1727-1788-syj300
62 Pages
-
5 Port Solenoid Valve S0700
111 Pages
-
5 Port Solenoid Valve VF
59 Pages
-
5 Port Solenoid Valve SV
127 Pages
-
VH
9 Pages
-
CUJ
41 Pages
-
AL
3 Pages
-
kj mm
9 Pages
-
AQ
4 Pages
-
SY3000/5000-X13
2 Pages
-
Series MB
24 Pages
-
Series LES
23 Pages
-
Series LEFB
16 Pages
-
Series PF3W
28 Pages
-
Floating Joint
7 Pages
-
Series IZS40/41/42
32 Pages
-
Series LEY
7 Pages
-
Series VHS
12 Pages
-
Series CY1S
28 Pages
-
SeriesCQ2/CQS/CQ
4 Pages
-
In-line Air Filter
12 Pages
-
5 Port Solenoid Valve
60 Pages
-
Series CQ2/CQS
2 Pages
-
AS series
2 Pages
-
corporate guide
13 Pages
-
ZP
69 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
MHZ
68 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
RSK
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
GLJ
65 Pages
-
MGJ
7 Pages
-
Mx
36 Pages
-
MXH
18 Pages
-
My3
56 Pages
-
my1b
20 Pages
-
CC
15 Pages
-
J
14 Pages
-
CQ2
51 Pages
-
standard cylinder
84 Pages
-
VFN
6 Pages
-
SY3000
246 Pages
-
SJ3A6
18 Pages
-
1301/IW
14 Pages
-
CHQ/CHDQ
19 Pages
-
AC
95 Pages
-
HAW
4 Pages
-
HAA
3 Pages
-
ZB
24 Pages
-
CRB2
35 Pages
-
CJ1
5 Pages
-
SYJ
62 Pages
-
SJ
78 Pages