cad

2 Port Solenoid Valve/Air Operated Valve For Dust Collector
40Pages

{{requestButtons}}

Catalog excerpts

2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 1

2 Port Solenoid Valve/Air Operated Valve New For Dust Collector [Excluding VXFC] Large port size is available. Piping Port size 50A to 100A added Flange type, Flange body type added RoHS Power consumption Enclosure 4.5 W Faston terminal type added IP65 Electrical entry “Faston” type terminal is IP40. Excluding size 23 Flange type Flange body type Mounting can be changed depending on the piping conditions. Orifice machining on the outlet is not necessary, so piping man hour is reduced! Flange body II type (Through hole mounting type) Installation Example Flange body I type (Flange mounting type) Direct piping type Solenoid valve type Flange body type Flange type Air operated type Variations Controller dedicated for operation Series VXFC Piping Type Port size Direct piping type Flange type Flange body I type Flange body II type Flange mounting type Through hole mounting type Electrical entry Solenoid valve type only 20A 25A Grommet 40A DIN terminal New 50A Conduit terminal New 65A Conduit New 80A New 90A New Solenoid valve type Air operated type 100A Series VXF2/VXFA2 Faston terminal CAT.ES70-47A

Open the catalog to page 1
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 2

2 Port Solenoid Valve/Air Operated Valve For Dust Collector Power consumption Enclosure IP65 4.5 W (Size 21, 22, 24, 25, 26, 27, 28) 8 W(Size 23) Low-noise construction Improved armature durability Metal noise reduced by the rubber bumper Flame resistant UL94V-0 conformed Silencer (Option) Piping variations 20A, 25A, 40A 50A, 65A, 80A New 90A, 100A Built-in full-wave rectifier type (AC specification) Improved durability Noise reduction Reduced apparent power Low-noise construction Service life is extended by the special construction. (compared with current shading coil) 11 VA 18 VA 7 VA...

Open the catalog to page 2
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 3

Controller Dedicated For Operation/Series VXFC The valve controller turns ON/OFF many valves for the dust controller. Power supply voltage Number of output points 2 port solenoid valve Blow tube Nozzle Controller dedicated Dust including air inlet Dust exhaust port Two-time Hitting Function A two-time hitting function is adopted to improve the bag filter dusting efficiency. Turn ON the DIP switch for two-time hitting (OFF for one-time hitting). (Effective up to the number of setting channels) Operation sequence diagram Two-time hitting only for CH2 Two-lime hilling | —:|iiec. Power switch...

Open the catalog to page 3
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 4

Series VXF2 Solenoid Valve Type Common Specifications/Selection Steps Specifications Solenoid Valve Type VXF21A Part no. Orifice size VXF22A 22 mmø VXF23A 28 44 VXF24A VXF25A B 70 53 A VXF26B C D VXF27B 80 VXF28B 90 100 Air Fluid Minimum operating pressure MPa 0.03 0.1 Maximum operating pressure MPa 0.7 Fluid temperature C −10 (No freezing) to 60 Ambient temperature C 5 to 60 Coil insulation type Class B Enclosure IP65 Allowable voltage fluctuation V Power consumption 10% of rated voltage AC VA 7 10 7 DC W 4.5 8 4.5 Solenoid Coil Specifications Normally Closed (N.C.) DC Specification AC...

Open the catalog to page 4
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 5

2 Port Solenoid Valve For Dust Collector Series VXF2 RoHS How to Order Solenoid Valve Type VXF2 1 A A A Common Specifications Diaphragm/Main valve material NBR/POM Coil insulation type Piping Port size Port Symbol size 1 2 3 4 65A Piping 20A 5 Symbol 6 7 8 25A 40A A Direct piping type A B Diaphragm/ Symbol Main valve material A B With/without silencer NBR/POM Voltage – Electrical entry Symbol Voltage Without NBR/POM Electrical entry With Direct piping type A B C D Material – With/without silencer Class B Direct piping type Grommet A 24 VDC B C D E F G H J K L M N P Q R S T U V W 100 VAC 50A...

Open the catalog to page 5
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 6

Series VXFA2 Air Operated Type Common Specifications/Selection Steps Specifications Air Operated Type VXFA21AA Part no. Orifice size mmø VXFA22AA 22 VXFA23AA 28 44 VXFA24A B VXFA25(A,B)B A A 70 53 Fluid VXFA26(A,B,C,D)B A 80 VXFA27BB A VXFA28B B A 90 100 Air Minimum operating pressure MPa 0.03 0.1 Maximum operating pressure MPa 0.7 Fluid temperature C −10 (No freezing) to 60 Ambient temperature C 5 to 60 Selection Steps Step 1 Select the port size. Item Port size Step 2 Piping Item 3 1 2 3 4 5 6 7 8 q VXFA2 1 A A q Selection item Direct piping type Flange type Flange body I type Flange body...

Open the catalog to page 6
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 7

Series VXFA2 2 Port Air Operated Valve For Dust Collector RoHS How to Order Air Operated Type VXFA2 1 A A Piping Port size Symbol Port size 1 2 3 4 Piping 6 7 8 25A A Direct piping type 65A A B NBR/POM Without NBR/POM With A B Flange body II type B With/without silencer Direct piping type 80A Diaphragm/ Main valve material Direct piping type A B C D Diaphragm/Main valve material NBR/POM Material – With/without silencer Symbol 20A 5 Symbol Common Specifications Flange type 40A For 40A or less, silencer cannot be selected. 50A 90A 100A Flange type Flange type Flange body I type For other...

Open the catalog to page 7
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 8

Series VXF2/VXFA2 Other Special Options Electrical Option (Special voltage, with light) VXF2 1 A A Z 1A Enter standard product number. Electrical option Special voltage – Electrical entry/Electrical option Without DIN connector With light Special voltage Specifications Symbol 5 1A 1B 1C 1U 1D 1E 1F 1G 1H 1V 1J 1K 1L 1M 1W 1N 1P 1Q 1R 1Y 1S 1T 2A 2B 2C 2D 2E 2F 2G 2H 2V 2J 2K 2L 2M 2N 2P 2Q 2R 2S 2W 2T 3A 3B 3C 3D 3E 3F 3G 3H 3V 3J Voltage 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC 48 VAC 220 VAC 240 VAC 24 VAC 12 VDC...

Open the catalog to page 8
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 9

Series VXF2/VXFA2 Valve Characteristics The valve characteristics data was measured with the outlet piping length. The valve characteristics vary depending on the tank capacity, air supply, set pressure, outlet conditions (nozzle size, quantity, piping length), so please use these values as a guideline. 1. Response Time, Start-up Speed VXF2 Type VXFA2 Type Measuring conditions …Refer to the circuit below. Test circuit …VXF21A (Port size 3/4) VXF22A (Port size 1) Test sample Measuring conditions …Refer to the circuit below. Test circuit …VXFA21A (Port size 3/4) VXFA22A (Port size 1) Test...

Open the catalog to page 9
2 Port Solenoid Valve/Air Operated Valve For Dust Collector - 10

1. RGSpOnSG Tim©, Start-Up SpGGd | VXF2/For solenoid valve type, the piping length to the pilot valve should be 0 mm, ON Response Time Start-up Speed Piping length to the pilot valve (mm) Piping length to the pilot valve (mm) Piping length to the pilot valve (mm) Piping length to the pilot valve (mm) Piping length to the pilot valve (mm) Piping length to the pilot valve (mm)

Open the catalog to page 10

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36 Pages

  2. IDF series

    12 Pages

  3. MHL2 Series

    24 Pages

  4. JCM Serie

    18 Pages

  5. EX245 Series

    12 Pages

  6. SY

    268 Pages

  7. es70-44c-vx2

    52 Pages

  8. es50-37-kq2

    124 Pages

  9. ex-pcw

    23 Pages

  10. es20-230b-crb2

    59 Pages

  11. VH

    9 Pages

  12. CUJ

    41 Pages

  13. AL

    3 Pages

  14. kj mm

    9 Pages

  15. AQ

    4 Pages

  16. Series MB

    24 Pages

  17. Series LES

    23 Pages

  18. Series LEFB

    16 Pages

  19. Series PF3W

    28 Pages

  20. Series LEY

    7 Pages

  21. Series VHS

    12 Pages

  22. Series CY1S

    28 Pages

  23. AS series

    2 Pages

  24. ZP

    69 Pages

  25. ZFA

    14 Pages

  26. ZA

    13 Pages

  27. MHF

    32 Pages

  28. MHZ

    68 Pages

  29. CRB

    44 Pages

  30. D

    117 Pages

  31. RB

    23 Pages

  32. CEP

    44 Pages

  33. RSK

    30 Pages

  34. CLK

    51 Pages

  35. MK

    20 Pages

  36. GLJ

    65 Pages

  37. MGJ

    7 Pages

  38. Mx

    36 Pages

  39. MXH

    18 Pages

  40. My3

    56 Pages

  41. my1b

    20 Pages

  42. CC

    15 Pages

  43. J

    14 Pages

  44. CQ2

    51 Pages

  45. VFN

    6 Pages

  46. SY3000

    246 Pages

  47. SJ3A6

    18 Pages

  48. 1301/IW

    14 Pages

  49. CHQ/CHDQ

    19 Pages

  50. AC

    95 Pages

  51. HAW

    4 Pages

  52. HAA

    3 Pages

  53. ZB

    24 Pages

  54. CRB2

    35 Pages

  55. CJ1

    5 Pages

  56. SYJ

    62 Pages

  57. SJ

    78 Pages

Archived catalogs