Group: SMC
Catalog excerpts
GW System, 4 Branches Series EX500 ® Valve manifold and input unit manifold can be connected around the GW unit. Compatible with various protocols by replacing the GW unit. Compatible with 64-digital-outputs (16 points x 4 branches) and 64-digital-inputs (16 points x 4 branches). GW unit, Input unit manifold: IP65 Valve manifold including SI unit: IP67 Input unit Input unit
Open the catalog to page 1How to Order GW Unit GW Unit DeviceNet™ PROFIBUS DP EtherNet/IP™ Communication speed Configuration file Note 2) Applicable system Terminating resistor Power supply voltage I/O occupation area (Inputs/Outputs) Built into the unit (Switch setting) 11 to 25 VDC (Supplied by DeviceNet™ circuit, 50 mA or less) For valve Internal current consumption (Unit) Number of inputs Connection input device 64 inputs (16 inputs x 4 branches) The EX500 series input unit manifold (connection from communication port A to D) Supply voltage Supply current Number of outputs Connection output device 64 outputs (16...
Open the catalog to page 2GW Unit Dimensions/Parts Description Branch connector Note 2) Marker: BN-WH (Made by PHOENIX CONTACT) GATEWAY UNIT EX500 SERIES Branch connector Note 2) Marker: BN-WH (Made by PHOENIX CONTACT) 160 136 Communication connector (M12, 4 pins, socket type D) Communication connector (M12, 5 pins, socket reverse key) Power supply connector Note 1) Switch protective cover 4 x M5 (mounting hole) M3 Ground terminal Power supply connector Note 1) Communication connector (M12, 5 pins, plug reverse key) Switch protective cover Communication connector (M12, 5 pins, plug) Switch protective cover 4 x M5...
Open the catalog to page 3Series EX500 How to Order Input Manifold Input Unit Manifold How to Order Input Block M8 connector, 2 inputs, PNP specifications 1 M8 connector, 2 inputs, NPN specifications 2 M12 connector, 2 inputs, PNP specifications 3 M12 connector, 2 inputs, NPN specifications 4 5 M8 connector, 8 points integrated type, PNP specifications 6 M8 connector, 8 points integrated type, NPN specifications For options, refer to pages 2120 to 2122. Input unit Input block (M8 connector) Input block (M12 connector) End block DIN rail 8 points integrated type input block (M8 connector) How to Order Input Unit...
Open the catalog to page 4Input Unit Specifications EX500-IB1 Internal current consumption Number of inputs Connection block The EX500 series input block (mixed combination is possible) Connection block stations 2-input, input block: Max. 8 stations 8-input, input block: Max. 2 stations Operating temperature range Environment Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation) Operating humidity range Operating, Stored: 35 to 85%RH (with no condensation) Withstand voltage 1000 VAC for 1 minute between whole live part and enclosure 2 MΩ or more (500 VDC mega meter) between whole live part and...
Open the catalog to page 5Series EX500 Input Unit Manifold Dimensions/Parts Description Input block (M8) only Connector for input device connection (M8, 3 pins, socket) Branch connector (M12, 8 pins, plug) (Rail mounting pitch: 12.5) VOLTAGE INPUT IP CODE SERIAL NO. Marker: BN-WH (Made by PHOENIX CONTACT) Stations Rail length L1 Input block (M12) only Branch connector (M12, 8 pins, plug) DIN rail EX500-IB1 VOLTAGE INPUT IP CODE Stations Rail length L1 Marker: BN-WH (Made by PHOENIX CONTACT) (Rail mounting pitch: 12.5) Connector for input device connection (M12, 4 pins, socket)
Open the catalog to page 6Input Unit Manifold Exploded View w a Input unit Input block (M8 connector) Input block (M12 connector) PNP specifications ... : 1, NPN specifications ... : 2 PNP specifications ... : 3, NPN specifications ... : 4 Input block (M8 connector) 8 points integrated type : No. based on L dimension (Refer to the table below.) How to add input block stations z Loosen the screws (2 places) that hold the end block. x Separate the blocks at the locations where stations are to be added. c Attach the additional blocks to the DIN rail, and connect the blocks so that they fit together securely. v While...
Open the catalog to page 7Series EX500 How to Order SI Unit SI Unit S001 Applicable solenoid valve: Series SV For options, refer to pages 2120 to 2122. Model Internal current consumption Output type Output Sink/NPN (Positive common) Positive common compatible Solenoid valve (single, double) Relay output module (1 ouput, 2 outputs) Connection block Double solenoid valve, relay output module (2 outputs): Max. 8 stations Single solenoid valve, relay output module (1 output): Max. 16 stations Connection block stations Connection block supply current IP67 Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and...
Open the catalog to page 8How to Order SI Unit SI Unit Applicable solenoid valve: Series SY/VQC/S0700 Output specifications 0 1 NPN (Positive common) PNP (Negative common) For without EX9 output block For EX9 output block mounting For options, refer to pages 2120 to 2122. Model Internal current consumption Number of outputs Output type 16 points Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Connection block Positive common compatible Negative common compatible Solenoid valve (single, double) Solenoid valve (single, double) Connection block stations...
Open the catalog to page 9Series EX500 Options Output block/ Power block Features: • Possible to retrofit to the valve manifold, using the unused points. • 2-output/1-output block (M12 connector) • Positive/Negative common available as standard. • Possible to drive by up to 0.5 A per a point. (EX9-OEP) Output block How to Order Output Block How to Order Power Block Power cable with connector Internal power supply method (for low-wattage load) Integrated power supply method (for high-wattage load) Note) Refer to page 2169. When ordering separately: 10 pcs. Refer to page 2168. Order separately. Output Source/PNP...
Open the catalog to page 10Output Block Specifications EX9-OET1 Output connector Internal current consumption Output type Power supply method Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) 2 outputs Internal power supply method Integrated power supply method (Power block: supplied from EX9-PE1) Output device supply voltage Output device supply current 24 VDC Max. 42 mA/point (1.0 W/point) Note) Yellow LED (Lights up when power is turned ON.) Connector on the output device side M12 connector (5 pins, plug) Operating temperature range Environment 40 mA or less Source/PNP (Negative...
Open the catalog to page 11All SMC PNEUMATIC catalogs and technical brochures
-
SYJ300/500/700 Series
62 Pages
-
Vacuum Unit ZK2 Series
60 Pages
-
Air Cylinder CJ2 Series
117 Pages
-
AS-FS Series
36 Pages
-
IDF series
12 Pages
-
MHL2 Series
24 Pages
-
JCM Serie
18 Pages
-
EX245 Series
12 Pages
-
Pin Cylinder CJP2/CDJP2/CJP
19 Pages
-
5 Port Solenoid Valve VQC
63 Pages
-
5 Port Solenoid Valve VQ
79 Pages
-
SY
268 Pages
-
5-p0979-0980-hep500
2 Pages
-
5-p0977-0978-aep100
2 Pages
-
5-p0966-0971-lmu
5 Pages
-
5-p0960-0966-alb900
6 Pages
-
5-p0956-0960-ald600
5 Pages
-
5-p0948-0950-al800
3 Pages
-
es70-44c-vx2
52 Pages
-
es50-37-kq2
124 Pages
-
ex-pcw
23 Pages
-
1-p2124-2152-ex510
29 Pages
-
1-p2063-2073-ex260
11 Pages
-
4-p0147-0178-msu-mds
32 Pages
-
es20-230b-crb2
59 Pages
-
1-p1869-1878-vp3145
10 Pages
-
VP300/500/700 series
42 Pages
-
1-p1789-1829-vqz100
41 Pages
-
1-p1727-1788-syj300
62 Pages
-
5 Port Solenoid Valve S0700
111 Pages
-
5 Port Solenoid Valve VF
59 Pages
-
5 Port Solenoid Valve SV
127 Pages
-
VH
9 Pages
-
CUJ
41 Pages
-
AL
3 Pages
-
kj mm
9 Pages
-
AQ
4 Pages
-
SY3000/5000-X13
2 Pages
-
Series MB
24 Pages
-
Series LES
23 Pages
-
Series LEFB
16 Pages
-
Series PF3W
28 Pages
-
Series IDG?A/IDG
56 Pages
-
Floating Joint
7 Pages
-
Series IZS40/41/42
32 Pages
-
Series LEY
7 Pages
-
Series VHS
12 Pages
-
Series CY1S
28 Pages
-
SeriesCQ2/CQS/CQ
4 Pages
-
In-line Air Filter
12 Pages
-
5 Port Solenoid Valve
60 Pages
-
Series CQ2/CQS
2 Pages
-
AS series
2 Pages
-
corporate guide
13 Pages
-
ZP
69 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
MHZ
68 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
RSK
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
GLJ
65 Pages
-
MGJ
7 Pages
-
Mx
36 Pages
-
MXH
18 Pages
-
My3
56 Pages
-
my1b
20 Pages
-
CC
15 Pages
-
J
14 Pages
-
CQ2
51 Pages
-
standard cylinder
84 Pages
-
VFN
6 Pages
-
SY3000
246 Pages
-
SJ3A6
18 Pages
-
1301/IW
14 Pages
-
CHQ/CHDQ
19 Pages
-
AC
95 Pages
-
HAW
4 Pages
-
HAA
3 Pages
-
ZB
24 Pages
-
CRB2
35 Pages
-
CJ1
5 Pages
-
SYJ
62 Pages
-
SJ
78 Pages