1-p2111-2122-ex500 - 1

GW System, 4 Branches Series EX500 ® Valve manifold and input unit manifold can be connected around the GW unit. Compatible with various protocols by replacing the GW unit. Compatible with 64-digital-outputs (16 points x 4 branches) and 64-digital-inputs (16 points x 4 branches). GW unit, Input unit manifold: IP65 Valve manifold including SI unit: IP67 Input unit Input unit

Open the catalog to page 1
1-p2111-2122-ex500 - 2

How to Order GW Unit GW Unit DeviceNet™ PROFIBUS DP EtherNet/IP™ Communication speed Configuration file Note 2) Applicable system Terminating resistor Power supply voltage I/O occupation area (Inputs/Outputs) Built into the unit (Switch setting) 11 to 25 VDC (Supplied by DeviceNet™ circuit, 50 mA or less) For valve Internal current consumption (Unit) Number of inputs Connection input device 64 inputs (16 inputs x 4 branches) The EX500 series input unit manifold (connection from communication port A to D) Supply voltage Supply current Number of outputs Connection output device 64 outputs (16...

Open the catalog to page 2
1-p2111-2122-ex500 - 3

GW Unit Dimensions/Parts Description Branch connector Note 2) Marker: BN-WH (Made by PHOENIX CONTACT) GATEWAY UNIT EX500 SERIES Branch connector Note 2) Marker: BN-WH (Made by PHOENIX CONTACT) 160 136 Communication connector (M12, 4 pins, socket type D) Communication connector (M12, 5 pins, socket reverse key) Power supply connector Note 1) Switch protective cover 4 x M5 (mounting hole) M3 Ground terminal Power supply connector Note 1) Communication connector (M12, 5 pins, plug reverse key) Switch protective cover Communication connector (M12, 5 pins, plug) Switch protective cover 4 x M5...

Open the catalog to page 3
1-p2111-2122-ex500 - 4

Series EX500 How to Order Input Manifold Input Unit Manifold How to Order Input Block M8 connector, 2 inputs, PNP specifications 1 M8 connector, 2 inputs, NPN specifications 2 M12 connector, 2 inputs, PNP specifications 3 M12 connector, 2 inputs, NPN specifications 4 5 M8 connector, 8 points integrated type, PNP specifications 6 M8 connector, 8 points integrated type, NPN specifications For options, refer to pages 2120 to 2122. Input unit Input block (M8 connector) Input block (M12 connector) End block DIN rail 8 points integrated type input block (M8 connector) How to Order Input Unit...

Open the catalog to page 4
1-p2111-2122-ex500 - 5

Input Unit Specifications EX500-IB1 Internal current consumption Number of inputs Connection block The EX500 series input block (mixed combination is possible) Connection block stations 2-input, input block: Max. 8 stations 8-input, input block: Max. 2 stations Operating temperature range Environment Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation) Operating humidity range Operating, Stored: 35 to 85%RH (with no condensation) Withstand voltage 1000 VAC for 1 minute between whole live part and enclosure 2 MΩ or more (500 VDC mega meter) between whole live part and...

Open the catalog to page 5
1-p2111-2122-ex500 - 6

Series EX500 Input Unit Manifold Dimensions/Parts Description Input block (M8) only Connector for input device connection (M8, 3 pins, socket) Branch connector (M12, 8 pins, plug) (Rail mounting pitch: 12.5) VOLTAGE INPUT IP CODE SERIAL NO. Marker: BN-WH (Made by PHOENIX CONTACT) Stations Rail length L1 Input block (M12) only Branch connector (M12, 8 pins, plug) DIN rail EX500-IB1 VOLTAGE INPUT IP CODE Stations Rail length L1 Marker: BN-WH (Made by PHOENIX CONTACT) (Rail mounting pitch: 12.5) Connector for input device connection (M12, 4 pins, socket)

Open the catalog to page 6
1-p2111-2122-ex500 - 7

Input Unit Manifold Exploded View w a Input unit Input block (M8 connector) Input block (M12 connector) PNP specifications ... : 1, NPN specifications ... : 2 PNP specifications ... : 3, NPN specifications ... : 4 Input block (M8 connector) 8 points integrated type : No. based on L dimension (Refer to the table below.) How to add input block stations z Loosen the screws (2 places) that hold the end block. x Separate the blocks at the locations where stations are to be added. c Attach the additional blocks to the DIN rail, and connect the blocks so that they fit together securely. v While...

Open the catalog to page 7
1-p2111-2122-ex500 - 8

Series EX500 How to Order SI Unit SI Unit S001 Applicable solenoid valve: Series SV For options, refer to pages 2120 to 2122. Model Internal current consumption Output type Output Sink/NPN (Positive common) Positive common compatible Solenoid valve (single, double) Relay output module (1 ouput, 2 outputs) Connection block Double solenoid valve, relay output module (2 outputs): Max. 8 stations Single solenoid valve, relay output module (1 output): Max. 16 stations Connection block stations Connection block supply current IP67 Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and...

Open the catalog to page 8
1-p2111-2122-ex500 - 9

How to Order SI Unit SI Unit Applicable solenoid valve: Series SY/VQC/S0700 Output specifications 0 1 NPN (Positive common) PNP (Negative common) For without EX9 output block For EX9 output block mounting For options, refer to pages 2120 to 2122. Model Internal current consumption Number of outputs Output type 16 points Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common) Connection block Positive common compatible Negative common compatible Solenoid valve (single, double) Solenoid valve (single, double) Connection block stations...

Open the catalog to page 9
1-p2111-2122-ex500 - 10

Series EX500 Options Output block/ Power block Features: • Possible to retrofit to the valve manifold, using the unused points. • 2-output/1-output block (M12 connector) • Positive/Negative common available as standard. • Possible to drive by up to 0.5 A per a point. (EX9-OEP) Output block How to Order Output Block How to Order Power Block Power cable with connector Internal power supply method (for low-wattage load) Integrated power supply method (for high-wattage load) Note) Refer to page 2169. When ordering separately: 10 pcs. Refer to page 2168. Order separately. Output Source/PNP...

Open the catalog to page 10
1-p2111-2122-ex500 - 11

Output Block Specifications EX9-OET1 Output connector Internal current consumption Output type Power supply method Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) 2 outputs Internal power supply method Integrated power supply method (Power block: supplied from EX9-PE1) Output device supply voltage Output device supply current 24 VDC Max. 42 mA/point (1.0 W/point) Note) Yellow LED (Lights up when power is turned ON.) Connector on the output device side M12 connector (5 pins, plug) Operating temperature range Environment 40 mA or less Source/PNP (Negative...

Open the catalog to page 11

All SMC PNEUMATIC catalogs and technical brochures

  1. AS-FS Series

    36 Pages

  2. IDF series

    12 Pages

  3. MHL2 Series

    24 Pages

  4. JCM Serie

    18 Pages

  5. EX245 Series

    12 Pages

  6. SY

    268 Pages

  7. es70-44c-vx2

    52 Pages

  8. es50-37-kq2

    124 Pages

  9. ex-pcw

    23 Pages

  10. es20-230b-crb2

    59 Pages

  11. VH

    9 Pages

  12. CUJ

    41 Pages

  13. AL

    3 Pages

  14. kj mm

    9 Pages

  15. AQ

    4 Pages

  16. Series MB

    24 Pages

  17. Series LES

    23 Pages

  18. Series LEFB

    16 Pages

  19. Series PF3W

    28 Pages

  20. Series LEY

    7 Pages

  21. Series VHS

    12 Pages

  22. Series CY1S

    28 Pages

  23. AS series

    2 Pages

  24. ZP

    69 Pages

  25. ZFA

    14 Pages

  26. ZA

    13 Pages

  27. MHF

    32 Pages

  28. MHZ

    68 Pages

  29. CRB

    44 Pages

  30. D

    117 Pages

  31. RB

    23 Pages

  32. CEP

    44 Pages

  33. RSK

    30 Pages

  34. CLK

    51 Pages

  35. MK

    20 Pages

  36. GLJ

    65 Pages

  37. MGJ

    7 Pages

  38. Mx

    36 Pages

  39. MXH

    18 Pages

  40. My3

    56 Pages

  41. my1b

    20 Pages

  42. CC

    15 Pages

  43. J

    14 Pages

  44. CQ2

    51 Pages

  45. VFN

    6 Pages

  46. SY3000

    246 Pages

  47. SJ3A6

    18 Pages

  48. 1301/IW

    14 Pages

  49. CHQ/CHDQ

    19 Pages

  50. AC

    95 Pages

  51. HAW

    4 Pages

  52. HAA

    3 Pages

  53. ZB

    24 Pages

  54. CRB2

    35 Pages

  55. CJ1

    5 Pages

  56. SYJ

    62 Pages

  57. SJ

    78 Pages

Archived catalogs