This cable connects the magnet to the Magsafe Control Unit. It has a 4 waycircular, bayonet locking connector at one end for connection to the magnet
and open wires at the other for connection via a gland into the control unit. The controller is designed to complement the Magsafesystem by offering a local
access controller with ‘traffic
light’ entry condition indication. Connection is made via
a standard 8 way connection provided on the Magsafecontrol units. Mounting is provided via M6 bolts in theend brackets top and bottom.The controller has a selector switch for Enter andmachine Run. Above the selector switch is the ‘traffic
light’ system that provides the operator with the entry
status indication. The red LED indicates that the
magnets are closed / door locked and the machine is running. To open the
door / release the magnets the selector switch is turned to the Enter position.
The amber LED will come on during the machine stopping time / run down
timer setting. When this is completed the green LED will come on to indicatethat the magnets have been released / the door is unlocked and the operator
can enter. Cable X Cable Y >
MAGSAFE
Local Access Controller Control Units The control units come in 2 options, offering thefacility for up to 4 monitored magnets from a
single controller or up to 8 monitored magnets
(16 un-monitored magnets) from a single
controller. The control unit contains all the
control electronics for the Magsafe system.Both boxes come with a standard 8 way connection for the Local AccessController, Run down timers for gate release, E-Stop inputs, External Device
Monitoring (
EDM) and LED output display with output signals for driving a
PLC input. The box can be used in conjunction with the standard Smartscan
Local Access Controller or the user can configure their own access control
interface. The control units come in IP40 boxes with glanded
industrial connectors for
the magnet cable connections, power supply input and the interface cable to
the machine control panel. CD227/080906HANDBOOK 7 >