Catalogue 8000 Series Handbook
www.smartscan.com
print switch display
Page / 21
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
Smartscan - 15203, 62920, 208557, 68106, 81145, 17217
/ 21
See other catalogues for Smartscan
Text version of the page

ACCESSORIES 31 32 ACCESSORIES

Inductive Loop Controller Mirror Units Typical applications include industrial conveyor systems where forklift truck manufacturer access is required to load and unload industrial pallets. Control of access doors e.g. warehouse doors for fork lift entry and exit areas for loading and unloading.As a pallet moves down the conveyor andenters the load / unload station. The fork lifttruck passing over the inductive loops provide mute signals to the inductive loop controller which initiates the inductive loop controller’ssafety outputs to provide mute signals for the light curtain. At this point the forklift can interrupt the sensing field of the safety light curtain at the load or unload station without interruption to machine operation.For safety, both inductive loops have timers, which limits the length of time the system remains in a muted state.These timers can be adjusted to suit specific applications. The timer settings would bedeterminedfrom the machine risk assessment.The mute signal outputs from the inductive loop controller are de-activated once the forklift truck clears the inductiveloops. The safety light curtain returns to its normal status reinstating the safety integrity at the load / unload station. Two or three sides of a machine can be safeguarded with a single light curtain by using mirrors to deflect the light curtain’s infra-red beams.The Smartscan mirror system provides a sturdy floor mounting kittogether with an aluminium column for mounting the mirror. The mirror assembly simply slots onto the column and can be adjusted to the height required for the application.The special mounting stand enables the mirror unit to be rotated through 360 degrees while also allowing full adjustment in all axes. Important note - If the forklift truck is within the sensing field of the light curtain and the time frame allowed for the two inductive loops expires, the system will de-activate the mute outputs of the inductive loopcontroller. Hence the light curtain will be re-activated and the system will trip in ‘Fail Industrial safe’ mode. To reset the system the forklift truck must be clear oftheinductive loops. The light curtain can be reset at the local reset station

.

ModelnumberDescription 083- 311Inductive loop controller Note: Mirrors cause a reduction in optical efficiency, reducing the effective range of the light curtain. Contact Smartscan Ltd or For more information refer to the section ‘Application Overview’. y our local Distributor for g uidance. 8000 SERIES8000 SERIES
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
pdf-page pdf di En 2008-12-49-02