APPLICATIONS OVERVIEW 23 24 SPECIFICATION
Figure 12 shows a rather more complex safety control system where the machinery is separated into four specific industrial safe zones, however the system uses much of the safety control functionality for the applications previously described in this section. 8000 Series Light curtains
Number of beams1- 4 Detection height500, 600, 900 and 1200mm RangePerimeter 0.5 – 30m (Model dependant)Parallel-beam muting 0.5 - 5m
Cross-beam muting 1 – 2.5m Figure 12 Light typeIR 880nm Response time40ms Operating temperature0 ° C to +50 ° C
Light curtain enclosure IP66 Power supply 24V DC 2A ± 10% Current consumption250mA Light curtain connectionCircular, bayonet locking IP68 FinishAluminium chromate treated, yellow polyester powder coated ClassificationBS EN 61496-1 Type 2BS IEC 61496-2 Type 2BS EN 954-1 Category 3 Warranty1 Year OUTPUTS Safety Outputs OSSD1 & OSSD22 X N/O fail-safe switching contacts each rated at 110 V 2A Status Output Relay1 x N/O switching contact rated at 110V 1A Mute OutputElectronic output. MUTE ON = 0V Status IndicationStatus & condition LED’s on Light Curtain INPUTS Safety Monitoring (
EDM)ON = +24V DC ActivateCombined restart and override. ON = +24V DC Muting M1 and M2Two circular IP68 bayonet locking connectors. One for each independent muting channel Mute Enable3 >
rd mute channel ON = +24V DC Mode selectCross-beam mute. ON = +24V DCParallel-beam mute. ON = 0V >
Certificate Number: AV EC 2027 Certificate Number: MCK/01/046 The application pictures included are for illustrating end-of-linepackaging examples and not for specific product representation. Report Numbers: 288/4268608 288/4260461amtri veritas Type ExaminedFM27829 8000 SERIES8000 SERIES