| | | ONDOR | | |
| | | GNT30 MEDICAL SERIES single output power supply | | |
| | | |
| | | |
| | | Low Power Medical Power Supplies 30 Watt AC/DC Universal Input Power Supply | | SUMMARY | | |
| | | |
| | | |
| | | • 90-264 Vac input range • Overvoltage and short circuit protection • Approved to UL, CSA and EN Standards • Small 50 mm x 80 mm footprint • Class II input available (G2T30) The GNT30 Series is a 30 W universal input AC/DC Power supply in a very small footprint. With the medical approvals the GNT30 is ideal for a variety of medical device applications including, small single board computers, battery charging, and running small motors, pumps, and solenoids. The series with full approval to EN60601-1 Standard improves design-in time, and reduces end system compliance costs. All specifications are typical at nominal input, full load at 25 OC unless otherwise stated | | |
| | | SPECIFICATIONS | | |
| | | |
| | | |
| | | | | | | | | | | OUPUT SPECIFICATIONS | | | | Output Power | 150 l.f.m. airflow | 30 Watts max.(See note 4 | | | | Total Regulation | | See table | | | | Turn-on time | | 1.5 s max. | | | | Transient response | 0.25 A/ms 50% load 3.5% max. dev. 1 ms recovery deviation to 1% | | | | Temperature Coefficient | | +/-0.03%/oC | | | | Overvoltage protection | | 125% +/-10% | | | | Short Circuit protection | Power cycling | Yes | | | | | | | | EMC INFORMATION | | | | Conducted emissions | EN55011 | Level B | | | | Radiated emissions | EN55011 | Level A | | | | Line freq. harmonics | EN61000-3-2 | Complies | | | | Voltage fluctuations | EN61000-3-3 | Complies | | | | ESD Air | EN61000-4-2 | 8 kV contact | | | | ESD Contact | EN61000-4-2 | 6 kV air | | | | Radiated immunity | EN61000-4-3 | 3 V/m | | | | Fast Transients (EFT) | EN61000-4-4 | 2 kV | | | | Line surge immunity | EN61000-4-5 | 1 kV diff /2 kV cm | | | | Conducted immunity | EN61000-4-6 | 3 V rms | | | | Power freq. mag. field | EN61000-4-8 | 3 A/m | | | | Voltage dip immunity | EN61000-4-11 | 5 cycles 40 % vnom 0.5 Watts. 25 cycles 70 % vnom 20 W | | | | | | | | | | | | | | | | | | INPUT SPECIFICATIONS | | | | Input Voltage range | Universal input | 100-240 nom (90 - 264 max) Vac | | | | Input frequency | | 55 Hz +/- 10 Hz | | | | Input surge current | | 32 A max. | | | | Ground Leakage current | 132 Vac 60 Hz | 100 nA (180 nA single fault) | | | | Input current | 120 Vac | 0.6 A | | | | | 230 Vac | 0.37 A | | | | Input fuse | F1,F2 | 2.5 A | | | | | | | | ENVIRONMENTAL SPECIFICATIONS | | | | Thermal Performance | operating ambient (see chart) | 0-50 oC | | | | | non-operating | -40 to +85 oC | | | | | 0 - 50 oC 150 l.f.m (See note 4.) | 30 Watts | | | | | 50 -70 oC ambient 150 l.f.m | derate 2% /oC | | | | Relative Humidity | non-condensing | 0% - 95% RH | | | | Maximum Altitude | operating / non-operating | 10,000 ft. / 40,000 ft. max. | | | | Vibration | Operating Non-operating | 1.5 g 20-2000 Hz 5 g 20-2000 Hz rms | | | | Shock | Operating Non-operating | 20 gpk 10 ms, half-sine 40 gpk 10 ms half-sine | | | | | | | | | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | |