1
Product information
2
Recommendations
3
Product data Page ............. 3Page ............. 16 Single row cylindrical roller bearings d 25 – 35 mm
B rrrr r
4 12341 r
3 rr
121 rr
3 4 D D d F d d d
1 E
Type NUType NJType NUPType N PrincipalBasic load ratingsFatigueSpeed ratingsMassDesignationsdimensions dynamicstatic load ReferenceLimitingBearingBearing withAlternative limit speedspeedwithstandard cagestandarddDBCC >
1) P >
u standardcage designs cage mmkNkNr/min kg– 25 621746,536,54,5512 00015 0000,28 NU 305 ECPJ, ML cont.621746,536,54,5512 00015 0000,29 NJ 305 ECPJ, ML 621746,536,54,5512 00015 0000,25 NUP 305 ECPJ, ML 621746,536,54,5512 00015 0000,24 N 305 ECP – 622464556,9512 00015 0000,38 NU 2305 ECPJ, ML 622464556,9512 00015 0000,39 NJ 2305 ECPML 622464556,9512 00015 0000,38 NUP 2305 ECPML30 551317,917,31,8614 00015 0000,12 NU 1006– 62164436,54,5513 00014 0000,23 NU 206 ECPJ, ML 62164436,54,5513 00014 0000,24 NJ 206 ECPJ, ML 62164436,54,5513 00014 0000,22 NUP 206 ECPML 62164436,54,5513 00014 0000,20 N 206 ECP– 622055496,113 00014 0000,26 NU 2206 ECPJ, ML 622055496,113 00014 0000,27 NJ 2206 ECPJ, ML 622055496,113 00014 0000,27 NUP 2206 ECPML 721958,5486,211 00012 0000,40 NU 306 ECPJ, M, ML 721958,5486,211 00012 0000,41 NJ 306 ECPJ, M, ML 721958,5486,211 00012 0000,38 NUP 306 ECPJ, M, ML 721958,5486,211 00012 0000,36 N 306 ECP– 722783759,6511 00012 0000,53 NU 2306 ECPML 722783759,6511 00012 0000,54 NJ 2306 ECPML 722783759,6511 00012 0000,55 NUP 2306 ECPML 902360,5536,89 00011 0000,75 NU 406– 902360,5536,89 00011 0000,77 NJ 406–35 621435,8384,5512 00013 0000,16 NU 1007 ECP– 721756486,111 00012 0000,33 NU 207 ECP J, M, ML 721756486,111 00012 0000,33 NJ 207 ECP J, M, ML 721756486,111 00012 0000,31 NUP 207 ECPJ, M, ML 721756486,111 00012 0000,30 N 207 ECP– 722369,5638,1511 00012 0000,40 NU 2207 ECPJ, ML 722369,5638,1511 00012 0000,41 NJ 2207 ECPJ, ML 722369,5638,1511 00012 0000,42 NUP 2207 ECPML >
The designations of SKF Explorer class bearings are printed in blue 1) When ordering bearings with an alternative standard cage the suffix of the standard cage has to be replaced by the suffix of the cage in question. e.g. NU 305 ECP becomes NU 305ECML 34