Technical data Designation
Max. operating pressure Permissible operating temperature Number of outlets Max. length of industrial pipes Tubing
Output of pump element Reservoir capacity Greases
Weight
System of protection
LAGD 1000/B
150 bars (2 175 psi)
-10 to60°C(14tol40°F)
6 to 12
6 m (19,7 ft)
6 xl,25 mm (0,05 in)
1 cm3/min (0,061 in3/min)
1 litre (33,8 US fl. oz)
up to NLGI grade 2
Flow pressure < 300 mbar
5,8 kg (12,8 lbs)
IP65
LAGD 1000/DC
150 bars (2 175 psi)
-25 to 75 °C (-13 to 167 °F)
10to20
6 m (19,7 ft)
6 xl,25 mm (0,05 in)
2 cmVmin (0,122 inVmin)
1 litre (33,8 US fl. oz)
up to NLGI grade 2
Flow pressure < 700 mbar
3,7 kg (8,2 lbs)
IP65
LAGD 1000/AC
150 bars (2 175 psi)
-25to60°C(-13to 140°F)
10 to 20
6 m (19,7 ft)
6 x 1,25 mm (0,05 in)
2 cmVmin (0,122 inVmin)
1 litre (33,8 US fl. oz)
up to NLGI grade 2
Flow pressure < 700 mbar
4,8 kg (10,6 lbs)
IP65
Electrical specifications Power connection
Rated voltage Power consumption Battery type
Type power input at 20 °C (68 °F) and max. operating pressure
Battery pack life
n/a 
DIN EN 175 301-803, plug supplied
24V DC
n/a
n/a
0,5 A
 DINEN 175 301-803,
plug supplied
18V 16 Ah alkaline
110 - 240V50/60 Hz
n/a
n/a
1.3A/110V
0.4A/230V
12 months or 1 lubricator filling (which ever comes first), when installed by end of the battery pack expiry date.
©SKF 2006/12
® SKF is a registered trademark of the SKF Group
SKF Maintenance Products
www.mapro.skf.com www.skf.com/mount
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless permission is granted Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of use of the information contained herein.
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
pdf-page pdf di En 2008-12-49-01