Catalogue Sitron's Line Of Conductive Level Switches
www.sitron.com
print switch display
Page / 12
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
Sitron - 145157, 130815, 2905, 5452, 3075, 81131, 83072
/ 12
See other catalogues for Sitron
Text version of the page
SSitron
SPECIFICATIONS
MODELS
BS16
CN16D
E
L 1 3/4' J I_ 4 3/8" _
(44m) (111mm)
Control of high and low level for conductive level probes
24 Vdc (+/- 10%) 115 or 230 Vac (50/60Hz)
2 VA
0,5 to 50K Ohms (potentiometer)
Relay (SPDT) 5A max (250Vac)
0,1 to 5 seconds (adjustable) 14° to 140°F (-10 to 60°C) ABS
DIN rail or screws IP 40
11 3/4" J I_ 4 3/8" _
(44m) (111mm)
Control of 2 different levels for conductive level probes
24 Vdc (+/- 10%) 115 or 230 Vac (50/60Hz)
3 VA
0,5 to 50K Ohms (potentiometer)
2 Relay (SPDT) 5A max (250Vac)
1 second 14° to 140°F (-10 to 60°C)
ABS
DIN rail or screws
IP 40
Application
Operating
Voltage
Current
Consumption
Sensitivity
adjustment
Output Time delay
Operating Temperature
Enclosure
material
Mounting
Class protection
CL1 DC
CL2 DC
Electrical connections
MODELS
Sensitivity adjustment
Sensitivity adjustment
Time Delay
Time Delay
24 Vdc +/- 10%
Max. 2VA
Cable gland with %"NPT conduit entry
or M12 connector Relay (SPDT)
5A max (250Vac) 12V - 100Hz
0,5 to 50K Ohms (potentiometer) 0,1 to 5 seconds (adjustable)
1/2" ... 1 %" BSP or NPT sanitary and flanges
Single - 316 Stainless Steel fixed rod
0,33 to 6,57 ft (100mm to 2.000mm)
Glass filled nylon
290 PSI (20 Bar) 14 to 248° F
(-10 to 120°C)
NEMA 4 (IP 65)
Level detection of conductive liquids in tanks and pipes
24 Vdc +/- 10% Max. 2VA
Cable gland with 1,4"NPT conduit entry or M12 connector
Relay (SPDT) 5A max (250Vac)
12V - 100Hz
0,5 to 50K Ohms (potentiometer)
0,1 to 5 seconds (adjustable)
3/4" ... 1 %" BSP or NPT sanitary and flanges
high and low -316 Stainless Steel fixed rod
0,33 to 6,57 ft (100mm to 2.000mm) Glass filled nylon
290 PSI (20 Bar)
14 to 248° F
(-10 to 120°C)
NEMA 4 (IP 65)
Application Operating voltage
Current Consumption
Electrical connection Output
Output voltage for
the electrodes Sensitivity adjustment
Time delay
Proccess connection
Electrodes
Length
Enclosure Material
Max pressure
Temperature operation
Class protection