Text version of the page
Text version of the page
SPECIFICATIONS CLF 01 - Fixed rodCLR 01 - Removable rodCLE 01 - Pendular industrial electrode CLF 02 - Fixed rodsCLR 02 - Removable rodsCLE 02 - Pendular electrodesCLF 03 - Fixed rodsCLR 03 - Removable rods
CLE 03 - Pendular electrodesCLF 04 - Fixed rodsCLR 04 - Removable rodsCLE 04 - Pendular electrodesCLF 05 - Fixed rodsCLR 05 - Removable rodsCLE 05 - Pendular electrodes MODELS 3 ½” (89mm) 2 ½” (64mm) L 1
L 1
L 1
L 1
L 1
L 1
L 1
L 1L 1
L 4L 4
L 4L 5L 4L 5
L 3
L 3
L 3
L 3
L 3L 3
L 2
L 2
L 2
L 2
L 2
L 2L 2 L 2 L 1 > 1/4" 7/8” 5 1/4”(134mm) L1L1L 2 L1 L1 L1 L2 L2 L2 L3L4 L3L4L5 L3 ApplicationLevel of Conductive liquids in industrial tanks and industrial pipes Level of Conductive liquids in tanks and pipes Level of Conductive liquids in tanks and pipes Level of Conductive liquids in tanks and pipes Level of Conductive liquids in tanks and pipes ElectrodeLengthRod: 0,33 up to 6,57f(100mm up to 2000mm)Cable: 1,64” up to 65,7 ft(500mm up to 20000mm)Rod: 0,33 up to 6,57f(100mm up to 2000mm)Cable: 1,64” up to 65,7 ft(500mm up to 20000mm)Rod: 0,33 up to 6,57f(100mm up to 2000mm)Cable: 1,64” up to 65,7 ft(500mm up to 20000mm)Rod: 0,33 up to 6,57f(100mm up to 2000mm)Cable: 1,64” up to 65,7 ft(500mm up to 20000mm)Rod: 0,33 up to 6,57f(100mm up to 2000mm)Cable: 1,64” up to 65,7 ft(500mm up to 20000mm)
ElectricalconnectionCable gland with ½”NPTconduit entry Cable gland with ½”NPTconduit entry Cable gland with ½”NPTconduit entry Cable gland with ½”NPTconduit entry Cable gland with ½”NPTconduit entry 1 fixed rod1 removable rod1 pendular by cable2 fixed rods2 removable rods2 pendular by cable3 fixed rods3 removable rods3 pendular by cable4 fixed rods4 removable rods4 pendular by cable5 fixed rods5 removable rods5 pendular by cableEnclosureMaterialGlass filled nylonGlass filled nylonGlass filled nylonGlass filled nylonGlass filled nylonMax pressure290 PSI (20 Bar)290 PSI (20 Bar)290 PSI (20 Bar)290 PSI (20 Bar)290 PSI (20 Bar)TemperatureoperationClass protectionNEMA 4 (IP 65)NEMA 4 (IP 65)NEMA 4 (IP 65)NEMA 4 (IP 65)NEMA 4 (IP 65)
Processconnection1/2” … 1 ½” BSP or NPTsanitary and flanges1/2” … 1 ½” BSP or NPTsanitary and flanges1/2” … 1 ½” BSP or NPTsanitary and flanges1 ½” BSP or NPTsanitary and flanges1 ½” BSP or NPTsanitary and flanges
14 to 248º F(-10 to 120ºC)14 to 248º F(-10 to 120ºC)14 to 248º F(-10 to 120ºC)14 to 248º F(-10 to 120ºC)14 to 248º F(-10 to 120ºC) Sitron-USA, Inc. 21 West Nicholai St. Hicksville, NY 11801 Ph:(516) 935-8001 Fax: (516) 935-6001 e-mail: www.sitron.cominfo@sitron.com -
|