• Products
  • Catalogues
  • Projects
  • News & Trends
  • Exhibitions

Modular controller type 5TCOM - 2 Pages

  1. P. 1

  2. P. 2

Catalogue excerpts

TEMPERATURE CONTROLLER FOR HOT RUNNER MOULDING SYSTEMS Hot Runner Controls Mould Temperature Control Sequential Moulding Production Monitoring Parc Industriel Sud - Groissiat F - 01100 OYONNAX Tel (33) 04.74.77.34.53 Fax (33) 04.74.73.90.18 e-mail sise@sise.fr web: www.sise.fr SELF-TUNING CONTROL MODULE WITH EUROMAP 17 COMMUNICATION Ref: 5 TCOM 5TCOM_uk.indd : 220/240 V 50/60 Hz single phase : 0 to 230 V x 20 A (4600 W) Phase control or pulse triggered & zero crossing (Low voltage with addition of transformer) : Thermocouple Fe/Co (J) linearisation, accuracy 0,5% 0 to 500°C (or 32 to 932°F according to configuration) or Thermocouple K with linearisation, accuracy 0,5% 0 to 500°C (or 32 to 932°F according to configuration) : SELF-TUNING or programmable P.I. : COMMUNICATION via RS485 using EUROMAP 17 protocole Automatic and manual 2nd Setpoint Programmable softstart (either 15% / 100°C or rate °C/minute) Display of current intensity (A) : Open thermocouple (displays and stops heating) Inverted thermocouple (displays and stops heating) Upper / Lower deviation alarm (programmable) Centralised alarm (output from cabinet relays and via EUROMAP 17 link) TRIAC failure Load failure Fuse GRB 20A (on cabinet) Protection against supply overvoltage and module overheating : Allows transmission between moulding machine or PC and controllers, via RS485, according to EUROMAP 17 standard, of : - setpoints and process parameters etc... to controllers - actual temperature, alarms etc... to moulding machine or PC SUPPLY OUTPUT INPUT CONTROL FUNCTIONS SAFETY FEATURES EUROMAP 17 COMMUNICATION

 Open the catalogue to page 1

TEMPERATURE CONTROLLER FOR HOT RUNNER MOULDING SYSTEMS Hot Runner Controls Mould Temperature Control Sequential Moulding Production Monitoring Parc Industriel Sud - Groissiat F - 01100 OYONNAX Tel (33) 04.74.77.34.53 Fax (33) 04.74.73.90.18 e-mail sise@sise.fr web: www.sise.fr 5TCOM_uk.indd ACTUAL TEMPERATURE is displayed on the red display SETPOINT is displayed on the green display FUNCTION KEY : Several items of data can be displayed by successive operation. LEDS: 2nd Setpoint Softstart Upper deviation alarm Lower deviation alarm Load failure TRIAC failure AUTO function MANU function ACTUAL...

 Open the catalogue to page 2

All S.I.S.E. catalogues and technical brochures

  1. IS'TECH

    4 Pages

    En
  2. M series

    4 Pages

    En
  3. Moldscan option

    2 Pages

    En
  4. 8C2X cabinets

    2 Pages

    En

Archived catalogues