TEMPERATURE CONTROLLER FOR HOT RUNNER MOULDING SYSTEMS
Hot Runner Controls
Mould Temperature Control
Sequential Moulding
Production Monitoring
Parc Industriel Sud - Groissiat
F - 01100 OYONNAX
Tel (33) 04.74.77.34.53
Fax (33) 04.74.73.90.18
e-mail sise@sise.fr
web: www.sise.fr 5TCOM_uk.indd
ACTUAL TEMPERATURE is displayed on the red display
SETPOINT is displayed on the green display
FUNCTION KEY : Several items of data can be displayed by successive operation.
LEDS:
2nd Setpoint
Softstart
Upper deviation alarm
Lower deviation alarm
Load failure
TRIAC failure
AUTO function
MANU function
ACTUAL TEMPERATURE
(RED DIGITS)
SETPOINT
(GREEN DIGITS)
INCREASE AND
DECREASE KEYS
FUNCTION KEY
ON / OFF KEY
1
2
3
RED DISPLAY GREEN DISPLAY FUNCTION
1st push or Set of AUTO or MANU function
by operating p orq
2nd push xxx Display and set of 2nd setpoint
3rd push xx.x Power level used (%)
4th push xx.x Actual RMS current supplied at output (Ampere)
5th push ox.x Nominal power of heating elements (kW)
6th push 1 or Access to configuration parameters
(see detailed specifications) For specialists only.
7th push or
after 5 sec.
Actual
Temperature Setpoint Back to normal display.
1
2
3
|
|