• Products
  • Catalogues
  • Projects
  • News & Trends
  • Exhibitions

Control system for sequential moulding - 2 Pages

  1. P. 1

  2. P. 2

Catalogue excerpts

CONTROL SYSTEM FOR SEQUENTIAL MOULDING Hot Runner Controls Mould Temperature Control Sequential Moulding Production Monitoring Parc Industriel Sud - Groissiat F - 01100 OYONNAX Tel (33) 04.74.77.34.53 Fax (33) 04.74.73.90.18 e-mail sise@sise.fr web: www.sise.fr PROGRAMMING l Integrated multilingual user interface (keyboard, function keys, blue backlit screen), for the following functions: Ø Programming movements of valve gates Ø Load / Save 16 sequence files Ø Manual operation of valve gates Ø Cycle count and display of cycle times l Option : PC and Win’IS 2000 software under Windows offering further functions: Ø Offline programming (PC not connected to the control system) Ø Save sequence files on hard disk or floppy Ø Transfer sequence files from one control system to another Ø Display, print and analyze recorded data (Pressure curve, screw position curve opening / closing of valve gates...) CONTROL l 2 versions are available : Ø 4U high cabinet (picture) for controlling 4 to 12 valve gates Ø 9U high cabinet for controlling 4 to 20 valve gates l Control of actual pin position (limit switches) l Control of up to 5 openings / 5 closings per cycle l Each movement can be individually triggered by one of the following signals: Ø On time as a delay from injection start and/or hold start. Ø Screw position in %, in mm, or in cm3. Ø Injection pressure (value) Ø External signals (0/1 and/or analogic) - (option) IS’2000 IS2000_ uk.indd

 Open the catalogue to page 1

CONTROL SYSTEM FOR SEQUENTIAL MOULDING Hot Runner Controls Mould Temperature Control Sequential Moulding Production Monitoring Parc Industriel Sud - Groissiat F - 01100 OYONNAX Tel (33) 04.74.77.34.53 Fax (33) 04.74.73.90.18 e-mail sise@sise.fr web: www.sise.fr SAFETY l Alarm output on potential free contact, activated in case of: Ø Failure of hydraulic pressure (not used if no external power pack) Ø Safety for injection : at least one gate must be open on cycle start and during cycle Ø Failure of control cards l Alarm input from the press and/or from the hydraulic power pack. CONNECTIONS l Output...

 Open the catalogue to page 2

All S.I.S.E. catalogues and technical brochures

  1. IS'TECH

    4 Pages

    En
  2. M series

    4 Pages

    En
  3. Moldscan option

    2 Pages

    En
  4. 8C2X cabinets

    2 Pages

    En

Archived catalogues