GDU-01
Early warning of pressurised leaks No field calibration High detection range
Ultrasonic Gas Leak Detector
Ultrasonic gas leak detectors complement traditional gas detection methods by listening to the ultrasound emitted from a pressurised release. Detection is not affected by wind direction or gas dilution hence the ability to detect leaks at an early stage can be achieved.
3-D Gas Detection
The Simtronics GDU listens to the ultrasound generated from escaping gas in all directions. A release does not need to cross an optical path nor does it need to physically reach the unit for detection.
The GDU does not detect specific values of LEL or ppm, rather it listens for changes in background sound level.
PRESSURISED LEAKS
Detection requires a driving pressure of at least 2 bar, hence detection of gas accumulations or vapours is not possible. In basic terms the detected sound is proportional to the leak rate (mass flow rate].
Features
Instant On-line airborne leak detection Encapsulated resonant sensor ATEX proved, intrinsically safe Direct connection to DCS / PLC / F&G Continuous Active Measurement >60 dB range, no field set-up required Fully sealed and glanded construction >30m (100 ft) detection range Flexible mounting arrangment Performance target verification
Applications
• Offshore Gas / Oil Platforms
• FPSOs
• Onshore Gas Receiving Terminals
• Underground Gas Storage Facilities
• Gas Transmission Networks
• Aftercoolers / Fin Fans
• LNG regassification plants
• Gas fired power stations
• Compressor Halls
Benefits
Fast response
Robust packaging for all climates
Suitable for hazardous area use
Standard integration
Fail safe monitoring via control system
Wide dynamic detection range
No replaceable parts
Minimises number of devices required
Maximises detection coverage
True coverage can be demonstrated
Background noise is ignored by a threshold set in the control room and employing time delays. The GDU is delivered factory calibrated and needs no field adjustment or re-calibration.
PERFORMANCE TARGET VERIFICATION
Unlike other gas detection methods the GDU performance can be demonstrated at commissioning to comply with the site safety case. This is achieved using a pressure regulated inert test gas to simulate the required performance target.