Universal meter SUR-94 datasheet
3Pages

{{requestButtons}}

Catalog excerpts

Universal meter SUR-94 datasheet - 1

Universal meters SUR-94 meter with a large, 20 mm high, LED display universal input: 0/4-20 mA, 0-10V, 0-150 mV, RTD or TC 0, 2 or 4 REL / OC outputs analogue output: active or passive, power supply output: 24V DC RS-485 / Modbus RTU signal peak value detection free configuration software S-Config The SUR-94 meter is equipped with one universal input, type: 0/4-20 mA, 0-10V, 0-150 mV, Pt 100/500/1000 or TC (K, S, J, T, N, R, B, E). During the measurement process only one kind of input is available. Temperature of cold ends is compensated automatically. RTD and TC inputs feature with fully linearized characteristics. Thanks to wide range of characteristic curves (linear, square root, quadratic, user-defined and volume characteristic for cylindrical tanks) the meters may be used in various process control systems. The 24V DC / 100 mA output is designed to supply measuring transducers, and the RS-485 port enables data transmission in production process monitoring systems. The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. Moreover, the meter can be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter can be configured with the local keyboard or free S-Config software via the RS-485 communication port. SIMEX Ltd., Wielopole 11, 80-556 Gdansk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, www.simex.pl

Open the catalog to page 1
Universal meter SUR-94 datasheet - 2

QsimEX DIMENSIONS Panel cut-out dimensions EXAMPLARY PIN ASSIGNMENTS 85-260^ ACTIVE AC/DC current 85-260^ PASSIVE AC/DC^ isolated 6,5W current output | | version with 2 x REL and 1 x AO 0/4-20 mA, active version with 2 x OC and 1 x AO 4-20 mA, passive 85-260V AC/DC ^ ACTIVE j \ 6,5W voltage version with 2 x REL and 1 x AO 0/1-5V, 0/2-10V, active version with 4 x REL 0 : no output 1 : REL (for 2 and 4 outputs) 2 : OC (for 2 and 4 outputs) 3 : 2 x REL + 1 x AO (0/4-20 mA, active, non-isolated) 4 : 2 x OC + 1 x AO (0/4-20 mA, active, non-isolated) 9 : 2 x REL + 1 x AO (4-20 mA,...

Open the catalog to page 2
Universal meter SUR-94 datasheet - 3

Meters accessories SMP-99/94 to mount 96 x 48 mm size unit in place of 96 x 96 mm cut-out MOUNTING PLATES SMP-147/94 to mount 96 x 48 mm size unit in place of 144 x 72 mm cut-out BOARD THICKNESS BRACKETS / ADAPTORS SPH-07 1 ÷ 7 mm board thickness brackets (2 pcs) standard included with device SPH-05 1 ÷ 5 mm board thickness brackets (2 pcs) SPH-45 1 ÷ 45 mm board thickness brackets (2 pcs) SRH-94 brackets for mounting devices on DIN 35/7.5 or 15 rail (2 pcs) SOFTWARE S-Config 2 is used for the simultaneous detection of devices in multiple Modbus RTU networks and allows user to change the...

Open the catalog to page 3

All SIMEX Sp. z o.o. catalogs and technical brochures

  1. STH-42

    2 Pages

  2. SPP-638

    3 Pages

  3. SLC_30_46_47

    2 Pages

  4. SLN-44

    2 Pages

  5. SLE-42

    2 Pages

  6. SWZ-W610

    3 Pages

  7. SPP-N118

    3 Pages

  8. SPP-94

    3 Pages

  9. SPI-638

    3 Pages

  10. SPI-N118

    3 Pages

  11. SPI-94

    3 Pages

  12. STI-638

    3 Pages

  13. STI-N118

    3 Pages

  14. STI-94

    3 Pages

  15. STI-73

    3 Pages

  16. SLN-94

    3 Pages

  17. SLK-94T

    3 Pages

  18. SLIK-638

    3 Pages

  19. SLB-94

    3 Pages

  20. SLIK-94

    3 Pages

  21. SLIK-73

    3 Pages

  22. SLE-73

    3 Pages

  23. SLC-457

    3 Pages

  24. SLC-94

    3 Pages

  25. MultiCon

    19 Pages

  26. SCK-11

    1 Pages

Archived catalogs

  1. SWS-99

    1 Pages