Wire-Actuated Encoder SGP/1 Robust design with analog output and 6000 mm measurement length

27

Mounting note

When you attach the wire, it should be pulled out straight in line with the wire outlet.

initial position final posotion~5mmmeasuring rangemax. extension length

Recommendation: A 5 mm wire extension is recommended before the measurement starting point. This prevents the wire snapping back to the stop on rewinding.

Symbolic representation

Order

â– 

Order table

Feature Order data SpecificationsAdditional information Measurement range (mm) ...750 … 6000 in steps of 250 mmWire design

Wire-actuated encoder - 16025 3 . 1

S stainless steel wiremeasurement range max. 6000 mm SK steel wire, plastic-coatedmeasurement range max. 4000 mm P paraline, non-conducting, signal colormeasurement range max. 2800 mmType of connection

3 . 23

E1 EX

CBDFEA

screwed cable gland PG7cable Ø 3-6.5 mm for M12 connectorPotentiometer type

. 33

02 10 turns/wire(P01, P05, P10) 03 10 turns/hybrid(P01, P05, P10)Analog output MWI transducer 4 ... 20 mA

. 4

MWU transducer 0 ... 10 V P01 potentiometer 1 k P05 potentiometer 5 k

3 . 5

P10 potentiometer 10 kOperating temperature T1 -20 ... +80 °C T2 -40 ... +80 °Cmax. pull-in speed 800 mm/s

3 . 6

â– 

Order code

3 . 7

SGP/1

––––––

A B C D E F

Scope of delivery: SGP/1, User information Accessories: Guide roller Page 38 Electronic displays MA50 or MA10/4 Catalog 6 DisplayLine Additional information: General information and areas of application Page 4 cont.
Subject to technical alterations 03/2009

3 LinearLine | 3.1 Wire-Actuated Encoders www.siko.de


pageCatalog pdf di En 2012-02-07-13