catalogue search
|
You may also be interested in
Display, Magnetic strip, Signal conditioner, Linear encoder, Position indicator
Text version of the page
Wire-Actuated Encoder SGP/126Robust design with analog output and 6000 mm measurement lengthElectrical dataâ–Potentiometric encoder typeFeatureTechnical dataAdditional information Value of resistance 1, 2, 5, 10 kPull-out lengthO mm : 0â– Potentiometer optionFeature (Type 02)(Type 03)Linearity ±0.25 %±0.25 %Resistance tolerance±5 %±5 % Power rating1 W2 Wâ– MWI encoder type, current source (transducer*)FeatureTechnical dataAdditional information Output current4 … 20 mAPotentiometer10 k Operating voltage15 … 28 V DC Load resistance<500Wire-actuated encoder - 16025 . 1â–3 . 23MWU encoder type, voltage source 0 … 10 V DC (transducer*)FeatureTechnical dataAdditional information Output current0 … 10 V DCRecomm. load resistance2 … 10 k to GND Max. load15 mA Operating voltage15 … 28 V DC with 3 mA without load. 33Transducer s allow optimum adaptation of output current or output voltage to the measurement range. The transducer is preset at delivery to provide an output signal of 4 ... 20 mA (MWI) or 0 ... 10 V DC (MWU) between the starting point and the end point of the measurement range... 43 . 53Pin assignment. 6 3â–Potentiometric outputs P10SignalE1 (terminal)E12 (plug-in pin) Pobrown1Pewhite2Sgreen3N.C.4 Potentiometric outputs P01, P05, P103 . 7... kPeSPo â–MWI transducerSignalE1 (terminal)E12 (plug-in pin) I+11I-22N.C.33N.C.4 * Transducer MWIâ– MWU transducerSignalE1 (terminal)E12 (plug-in pin) +24 V DC11GND22U10 kR/I-transformerI-I+ out 33N.C.4 Transducer MWU 10 k R/U-transformer +UBGNDUout 3 LinearLine | 3.1 Wire-Actuated Encoders www.siko.de |