Catalogue Magnetic length measuring systems Micro incremental
www.siko.de
print switch display
Page / 16
SIKO - 3083, 208570
/ 16
See other catalogues for SIKO
Text version of the page

Magnetic Display MA100/2

96

This display interprets the data of distance and anglemeasurement captured by the magnetic sensor MS100/1. The display is widely and individually programmable and isalso available with integrated power pack and bench-tophousing.

48 85516.5max.5 89.5 42.5
9468 25.521.5

9

â– â– â– â–  â– â– â– 

high-contrast 12-digit LCD, dot matrixintegrated translation module for length and anglemeasurementResolution max. 1

147100 TG

m, precision class 10 mincremental/ reset functioninput for reference switchdirect input of reference/ offset value serial RS232/ RS485 interface as an option

5553 8
46 4.8 FeatureOrdering dataTechnical dataAdditional information Design EGpanel-mount housing, TGbench top housingaluminium profile, black anodized

A A

cutout 92 x 45 mm standard, Noryl GFN 2 SE 1, as snap-in module Operating voltage 424 V DC 1230 V AC 2115 V AC

B

20%standard 10% 10% Reference connection RMwith connectionstandard ROwithout (only bench-top housing)

C

Interface/ protocol XX/XXwithoutstandard S1/00RS232 with standard protocol S3/00RS485 with standard protocol

D

Switching output SOwithoutstandard SMwithonly for XX/XX interface

E

Display/ display range12-digit LCD dot matrix-9 999 999 … 9 999 999 + sign + units Connectionsensor pluggable: Mini-DINsupply: 9-pin screwed terminal strip (EG) Travel speedmax. 5 m/s (of the magnetic sensor)with 0.1–0.4 mm strip/ sensor gap Resolutionin mm 0.001/ 0.01/ 0.1/ 1/ 10in inch 0.001/ 0.01/ 0.1/ 1 Repeat accuracy 1 digit System accuracy (0.01 + 0.01 x L) mm [L in m]at T
U = 20 C; for magnetic strip type MB100 (10 m precision) Protection class/ Test mark3, according to IEC 801CE Signal inputreference switch Temperature rangesworking temperature: 0 ... +50 Cstorage temperature: –20 ... +80 C Type of protectionIP 40 acc. to DIN 40050 for whole unitIP 60 acc. to DIN 40050 for control panel inclusion Humidity95% rHcondensation not permitted 230/115 Volt version 24 Volt version Your order:–––––

MA100/2 A B C D E Features:

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics