Turbotron - flow meters for liquids - SIKA - #3

/ 27


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
Pages:


See other catalogues for SIKA

Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:16.00pt "Arial", sans-serif; } .font4 { font:21.00pt "Impact", sans-serif; } .font5 { font:10.00pt "Microsoft Sans Serif", sans-serif; } .font6 { font:7.00pt "Tahoma", sans-serif; } .font7 { font:8.00pt "Tahoma", sans-serif; } .font8 { font:10.00pt "Tahoma", sans-serif; } Technical data y-priced tandard and seria applications ree rotor, hig measurement accuracy, high resolution igh temperatures fuels Material pipe section brass plastic PPO brass stainless steel brass plastic PPO Measurement range: 2...40 l/min with special bearings for low flow rates with continuous flow max. 20 l/min Accuracy ± 1 % of range ± 1 % of range ± 0,5 % of range Reproducibility ± 0,2 % ± 0,2 % ± 0,1 % Signal output starting from 0.3 l/min Max. medium temperature 85 °C PN 10 150 °C pmax = 300 bar DN 15 85 °C PN 10 Nominal pressure Diameter Process connection %" BSP male thread with union nuts and flat seal %" BSP male thread or %" BSP female thread %" BSP male thread with union nuts and flat seal Sensor Hall effect sensor Hall effect sensor inductive proximity switch Output signal - pulse rate / K-factor - resolution - signal shape - signal current 855 pulses/liter 1,2 ml/pulse square wave signal NPN open collector max. 10 mA 915 pulses/liter 1,1 ml/pulse square wave signal NPN open collector max. 10 mA 1795 pulses/liter 0,6 ml/pulse square wave signal PNP or NPN open collector max. 50 mA Electrical connection 1,5 m of PVC cable, screened, (Tmax = 70 °C) or 4- pin plug connector M12x1 1,5 m silicone cable, screened (Tmax = 150 °C) 2 m of PVC cable, screened, (Tmax = 70 °C) or 4- pin plug connector M12x1 Power supply 4,5...24 VDC 10...30 VDC Type of protection IP 54 max. particle size in the medium 0,5 mm 1 Options Screen filter hat shape, mesh size 0,5 mm Tmax = 60 °C (continuous) = 85 °C (max. 1 h) — hat shape, mesh size 0,5 mm Tmax = 60 °C (continuous) = 85 °C (max. 1 h) Integrated temperature sensor Pt 100 or Pt 1000, 3 wire, class B (class A on request) 2 m of PVC cable, screened Pt 100 or Pt 1000, 3 wire, class B (class A on request) 2 m of PVC cable, screened WRAS * VTP has no WRAS-approval -3- SIKA Dr. Siebert & Kûhn GmbH & Co. KG, Struthweg 7-9, D-34260 Kaufungen, Tel.: +49 5605 803 +49 5605 803-54, e-mail: info@sika.net, www.SIKA.net

pageCatalog pdf di En 2012-02-06-08