Turbotron - flow meters for liquids - SIKA - #24

/ 27


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
Pages:


See other catalogues for SIKA

Text version of the page
Technical data
Signal inputFrequency signals of up to two identical flow sensors VT...15 VT...25 VT...40Display per channelLED green = okLED red = alarm Set point adjustmentusing two 16-position rotary switches, 16 different set points can be selected per channel Set point rangeVT...15:0,5...29,5 l/minSwitching hysteresis0,5 l/minVT... 25:3...100 l/min2...10 l/min VT...40:7...275 l/min3...35 l/minOutputstwo independent, potential free c/o contacts Max. contact rating30 VDC / 1 A150 VAC / 400 mA Power supply 12...24 VDC ±10 % CasingPlastic casings for assembly rail setup, approx. 17.5 x approx. 67 x 82 mm (W x D x H) Ambient temperature / storage temperature0...60 °C / -10...80 °C Dimensions Order code
Order number EU70500XXX2296 Connected turbine flow sensors VTH 15VTP 15 VTI 15, NPN VTI 15, PNP VTH 25 / VTM 25 VTI 25 VTH 40 / VTM 40 VTI 40H15D15I15P15H25P25H40P40 SIKADr.Siebert & Kühn GmbH&Co.KG, Struthweg7–9,D-34260 Kaufungen,Tel.:+49 5605 803-0, Fax: +49 5605 803-54, e-mail: info@sika.net,www.SIKA.net

pageCatalog pdf di En 2012-02-07-16