Turbotron - flow meters for liquids - SIKA - #22

/ 27


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
Pages:


See other catalogues for SIKA

Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:19.00pt "Verdana", sans-serif; } Set point table VT..15..VE (DN 15) Switch position 0 1 2 3 4 5 6 7 8 9 A B C D E F Set point decreasing flow (l/min)* 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,5 5,5 7,5 9,5 11,5 15,5 19,5 24,5 29,5 Set point increasing flow* 0,5 l/min bove the set point decreasing flow VT..25..VE (DN 25) Switch position 0 1 2 3 4 5 6 7 8 9 A B C D E F Set point decreasing flow (l/min)* 3 5 6 8 10 12 15 18 20 25 30 35 40 50 70 100 Set point increasing flow (l/min)* 5 _ _ 10 12 14 _ 20 22 27 33 38 44 55 75 105 VT..40..VE (DN 40) Switch position 0 1 2 3 4 5 6 7 8 9 A B C D E F Set point decreasing flow (l/min)* 7 10 15 20 25 30 35 40 50 65 80 100 130 160 200 275 Set point increasing flow (l/min)* 10 13 19 24 30 35 40 47 58 75 90 115 150 190 230 310 16-position ro-tary switch for set point adjust-ment * The specified values refer to operation with water at 20°C. Monitoring of fluids with higher viscosities is possible with the effect of deviations from the mentioned values. If you order at least 25 units, individual set point tables can be implemented. Technical data Set point range (with decreasing flow) / accuracy DN 15 0.5 ... 29.5 l/min / ±0,2 l/min and ±2% of set point DN 25 3 ... 100 l/min / ±0,8 l/min and ±4% of set point DN 40 7 ... 275 l/min / ±2,0 l/min and ±6% of set point Set point adjustment 16 different set points selectable by means of a 16-position rotary switch Output / max. contact rating only switching output: electrically insulated contact, opens in the case of lack of flow max. contact rating 125 VAC/DC, 100 mA switching output and pulse output: - switching output against power supply max. contact rating 100 mA - pulse output: flow-proportional frequency signal NPN, max. 100 mA Switching hysteresis 0,5 l/min (DN 15) 2...5 l/min (DN 25) 3...35 l/min (DN 40) Power supply 12...24 VDC Current consumption max. 25 mA Type of protection IP 54 with closed sleve and connected socket Casing Plastic PA, transparent Display, internal LED yellow = ok (flow) LED red = Alarm (lack of flow) Max. medium temperature Dependent on the maximum temperature of the used flow sensor, not exceeding 80°C Electr. connection 4-pin plug connector, M12x1 Order code_ Please order by a the corresponding selection in the order code, page 5, 11, or 17. -22- SIKA Dr. Siebert & Kûhn GmbH & Co. KG, Struthweg 7-9, D-34260 Kaufungen, Tel.: +49 5605 803-0, Fax: +49 5605 803-54, e-mail: info@sika.net, www.SIKA.net

pageCatalog pdf di En 2012-02-07-16