Set point table
VT..15..VE (DN 15)
Switch position
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Set point decreasing flow (l/min)*
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,5
5,5
7,5
9,5
11,5
15,5
19,5
24,5
29,5
Set point increasing
flow*
0,5 l/min bove the set point decreasing flow
VT..25..VE (DN 25)
Switch position
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Set point decreasing flow (l/min)*
3
5
6
8
10
12
15
18
20
25
30
35
40
50
70
100
Set point increasing flow (l/min)*
5
_
_
10
12
14
_
20
22
27
33
38
44
55
75
105
VT..40..VE (DN 40)
Switch position
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Set point decreasing flow (l/min)*
7
10
15
20
25
30
35
40
50
65
80
100
130
160
200
275
Set point increasing flow (l/min)*
10
13
19
24
30
35
40
47
58
75
90
115
150
190
230
310
16-position ro-tary switch for set point adjust-ment
* The specified values refer to operation with water at 20°C. Monitoring of fluids with higher viscosities is possible with the effect of deviations from the mentioned values.
If you order at least 25 units, individual set point tables can be implemented.
Technical data
Set point range (with decreasing flow) / accuracy
DN 15 0.5 ... 29.5 l/min / ±0,2 l/min and ±2% of set point DN 25 3 ... 100 l/min / ±0,8 l/min and ±4% of set point DN 40 7 ... 275 l/min / ±2,0 l/min and ±6% of set point
Set point adjustment
16 different set points selectable by means of a 16-position rotary switch
Output / max. contact rating
only switching output:
electrically insulated contact, opens in the case of lack of flow
max. contact rating 125 VAC/DC, 100 mA switching output and pulse output:
- switching output against power supply max. contact rating 100 mA
- pulse output: flow-proportional frequency signal NPN, max. 100 mA
Switching hysteresis
0,5 l/min (DN 15) 2...5 l/min (DN 25) 3...35 l/min (DN 40)
Power supply
12...24 VDC
Current consumption
max. 25 mA
Type of protection
IP 54 with closed sleve and connected socket
Casing
Plastic PA, transparent
Display, internal
LED yellow = ok (flow) LED red = Alarm (lack of flow)
Max. medium temperature
Dependent on the maximum temperature of the used flow sensor, not exceeding 80°C
Electr. connection
4-pin plug connector, M12x1
Order code_
Please order by a the corresponding selection in the order code, page 5, 11, or 17.