| | | Service Temperature Calibrators, Series TP 18 000 E and TP 17 000 M The professional solution for the servicing sector | | |
| | | |
| | | Exact temperature measurement and monitoring are "musts" in applications crucial to operational safety of machinery, ships and industrial installations. Regular inspection of the temperature sensors is used in these applications absolutely essential for economic and technical-safety reasons and is already prescribed as obligatory in many sectors. The SIKA service temperature calibrators, type-tested by Germanischer LLoyd (GL), are approved for use on sea-going ships and inland waterway vessels and in the offshore area. | | |
| | | Description: | | |
| | | |
| | | The service temperature calibrators contain an electronically controlled metal block with a bore for the reception of the test piece. Adapter sleeves are used for test pieces with smaller diameter. The block is mounted in a heat isulated housing . In front of the calibrator are the complete electronic system. The required temperature are set by a digital controller and automatically adjusted to the set value. Block value and set value are constantly shown on the 2-line, 4-digit, 7-segment LED display. | | |
| | | |
| | | All concerted | | |
| | | |
| | | |
| | | GL No. 11297-98 HH | | |
| | | |
| | | Temperature calibrators for applications in the: | | |
| | | |
| | | Shipping industry Energy-production and energy distribution sector Chemical and petrochemical industry Pharmaceutical industry Food industry And a great deal more | | |
| | | SIKA service calibrators for | | ection of: | | |
| | | |
| | | Inspection is performed by comparison of the temperature measured by the test piece and the block temperature indicated by the calibrator / calibration bath. Temperature switches/thermostats The test piece will insert into the block and connected to the external transducer. The switch setting respective to the switch point is signalled by reached temperature. A separate temperature measuring instrument is required for inspection. We recommend the use of our temperature measuring device TTScan. The inspection is performed by comparison of the temperature indicated on the external measuring instrument with the reference temperature of the calibrator / calibration bath. | | |
| | | ■ | | |
| | | |
| | | |
| | | Our service temperature calibrators are already a part of the standard equipment of the service technican in the above listed sectors. These compact devices are easy to transport and easy to operate and have all performance features required for "in-situ inspection". | | |
| | | |
| | | |
| | | A guarantee of 5 years is grant to all service calibrators which are calibrated and tested at least once per year by the SIKA DKD laboratory. | | |
| | | |
| | | SIKA Dr.Siebert & Kühn GmbH & Co. KG Struthweg 7-9 • 34260 Kaufungen • Germany • S.: +49 5605 803-0 • Fax: +49 5605 803-54 • e-mail: ¡nfo@slka.net • www.SIKA.net | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |