Text version of the page
5
SDD305SDD 310SDD 315SDD 215SDD120
G-VMAINS = 230 (rated mains voltage = 230V) Regen circuit Switch-on thresholdV DC-Link capacitanceµF 940700
External regen resistor valueΩ3325
Internal regen resistor valueΩ33 – 5025 – 50
Rated power of the internal regen resistorW66200 >
DC 420Switch-off levelV >
DC 400Over voltage protectionV >
DC 450Maximum rated power of the external regen resistorW400750Peak power of the internal regen resistor (maximum 1sec.)kW5.16.5 G-VMAINS = 400 (rated mains voltage = 400V) Switch-on thresholdV >
DC -730Switch-off levelV >
DC -690Over voltage protectionV >
DC -800Maximum rated power of the external regen resistor >
W
-1200Peak power of the internal regen resistor (maximum 1sec.) >
kW
-21 >
G-VMAINS = 480
(rated mains voltage = 4 >
80V)
Switch-on threshold >
V
DC -850Switch-off level >
V
DC -810Over voltage protection >
V
DC -900Maximum rated power of the external regen resistor >
W
-1500Peak power of the internal regen resistor (maximum 1sec.) >
kW
-27 >
Internal fusing
Auxiliary supply 24V (+24V to BGND)electronic fuseHolding brake supply 24V-BR (+24V-BR to BGND)electronic protection
Regen resistorelectronic protection >
Plug types
Auxiliary supply (X1A)Sauro CTF0300TCombicon 5, 3-pinPower supply (X1B)Power Combicon 7.62, 8-pin, 4mm²Power Combicon 7.62, 8-pin, 4mm²Feedback (X6, X7, X8)Sub-D 25-pin (female)Sub-D 25-pin (female)
Motor (X3, X4, X5)Power Combicon 7.62, 6-pin, 1.5mm²Power Combicon 7.62, 6-pin, 4mm² >
Mechanics
Height with / without plugsmm249472 / 378Widthmm114152
Depth with / without plugsmm300 / 225240
Weightkg310 >