Digital Multimeter
Open the catalog to page 1User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for the needs of high-precision, multifunction and 4.3” TFT-LCD, 480*272 Support dual display, Chinese and English Menu Built-in front panel accessible help system File management (support for U-disc and local storage) automatic measurement. Application fields Research Laboratory Development Laboratory Detection and Maintenance Calibration Laboratory Automatic Production Test Main Function Basic Measurement Function DC Voltage: 600 mV ~ 1000...
Open the catalog to page 2Special Features
Open the catalog to page 3Specifications Accuracy± ( % of Reading + count)[1] Test current or Load Resolution voltage Continuity Test Remarks: [1] Specifications are for 0.5 Hour warm-up, “Slow” measurement rate and calibration temperature 18℃ ~ 28℃ . [2] 10% over range on all ranges except for DCV 1000 V, ACV 750 V, DCI 10 A and ACI 10 A. [3] Specifications are for 4-wire measure or 2-wire measure under “REF” operation. ±0.2 Ω of extra errors will be generated if perform 2-wire measure without “REF” operation. [4] Plus 0.02 mV of error per 1 V after the first ±500 VDC. [5] 30 seconds OFF after 30 seconds ON is recommend...
Open the catalog to page 4SDM3045X Digital Multimeter Accuracy± ( % of Reading + count)1] Frequency Range Additional wave crest factor error ( not Sine ) [7] Wave crest coefficient Error (% Range) Remarks: [1] Specifications are for 0.5 Hour warm-up, “Slow” measurement rate and calibration temperature 18℃ ~ 28℃ . [2] 10% over range on all ranges except for DCV 1000 V, ACV 750 V, DCI 10 A and ACI 10 A. [3] Specifications are for amplitude of sine wave input > 5% of range. For inputs from 1% to 5% of range and <50 kHz, add 0.1% of range extra error. For 50 kHz to 100 kHz, add 0.1% of range extra error. [4] Plus 0.025 V...
Open the catalog to page 5Frequency and Period Characteristic Accuracy± (% of Reading + count)1 [1] Specifications are for 0.5 Hour warm-up, not include probe error. [2] Specifications are for 4-wire measure or 2-wire measure under "REF" operation. [3] Built-in cold terminal compensation for thermocouple, accuracy is ±2°C .
Open the catalog to page 6Measuring Method and other Characteristics DC Voltage Input Resistance Input Bias Current Input Protection 120 dB (For the 1 KΩ unbalanced resistance in LO lead, max ±500 VDC) 60 dB at “slow” measurement rate Resistance Testing Method 4-wire resistance or 2-wire resistance selectable Input Protection DC Current 600 μA sampling voltage < 33 mV Shunt Resistor Input Protection Rear panel : accessible 10 A,250 V fast-melt fuse Internal :12 A,250 V slow-melt fuse Continuity/Diode Test Measurement Method 1 mA ±5% constant-current source or open-circuit voltage Continuity Threshold Input Protection...
Open the catalog to page 7History Records Volatile Memory 10 K reading of history records Nonvolatile Memory 1 Gb Nand Flash, Mass storage configuration files and data files, Support U-disk external storage Math Functions Min/Max/Average, dBm, dB, Pass/Fail, Relative, Standard deviation, Hold, histogram, Trend chart, Bar chart General Specifications Power Supply AC 100 V ~ 120 V Mechanism Dimension Other Characteristics Display Screen 4.3” TFT-LCD with resolution 480*272 Full accuracy from 0℃ to 50℃ , 80% RH and 40℃ , non condensing Operation Environment Storage Temperature: -20℃ -70℃ Shock and Vibration: conforming to...
Open the catalog to page 8SDM3045X Digital Multimeter About SIGLENT SIGLENT is an international high-tech company, concentrating on R&D, sales, production and services of electronic test & measurement instruments. SIGLENT first began developing digital oscilloscopes independently in 2002. After more than a decade of continuous development, SIGLENT has extended its product line to include digital oscilloscopes, function/arbitrary waveform generators, digital multimeters, DC power supplies, spectrum analyzers, isolated handheld oscilloscopes and other general purpose test instrumentation. Since its first oscilloscope, the...
Open the catalog to page 921 Pages
21 Pages
10 Pages
15 Pages
6 Pages
48 Pages
10 Pages
3 Pages
7 Pages
197 Pages
59 Pages
7 Pages
13 Pages
12 Pages
9 Pages
10 Pages
8 Pages
10 Pages